HyQuest Solutions
ML-IoT/C and /N Operation Manual © Copyright
Page -
14
Issue 1.2 28 Jun, 2021
3.3
Sitename – GPS - Additional Sensor Port
“Sitename”
Used as a part of the FTP
filename when transferring data – or metadata
in other file formats.
“GPS Latitude”
- sent as metadata
“GPS Longitude”
- sent as metadata
“Additional Sensor Port”
- This allows the
user to select the additional ML-IoT port that is
used – and MUST be used in conjunction with
the jumpers/links on the PCB.
DigInp#2
: Used as a Tamper switch –
monitored every second only – for
open/closed.
SDI-12
: Used to monitor an extra 6 x SDI-12
data points from one or several SDI-12
sensors.
485 Modbus
: Future feature to monitor extra
Modbus data.
This main Config dialog allows you to connect
to the other configuration areas as described on
each button.