© 2018
Troubleshooting
MX3636-01 Rev. D
97
Type
Alert/Fault/Error Display
Buzzer Chirp Sequence
Possible Cause & Suggested Corrective Action
ERROR
ERROR 10
SLOWDOWN SWITCH
3 chirps per second once per
minute
VFD only. The operator tripped the fully Open or Close limit before
the Slowdown limit tripped. Check:
Slowdown limit wiring and adjustment
Adjustment of the limit ramps to verify that the limit switch is being
tripped. Manually trip the slowdown limit. OPEN SLOWDOWN or
CLOSE SLOWDOWN should appear on the display which indicates
that it is working properly.
FAIL
FAIL
Program Data Err
FAIL
3 chirps per second once per
minute
Try turning off the power to the operator and having the customer
re-seat all of the various connectors and cables.
Upload the latest software release. If the fail does not go away,
contact Technical Support.
a
cceSS
tHe
e
Vent
L
OG
tHrOuGH
tHe
u
Ser
m
enu
NOTE:
While you are viewing the event log, the gate operator is in Menu mode and cannot run open or close.
1. To enter the User Menu, press the Menu key twice.
2.
Press Next and scroll until “LG 0 (OFF)” appears in the display.
3. Press Select. LG blinks.
4. Press Next to change the number to 1,
LG 1 (ON)
VIEW EVENT LOG
5. Press Select. The most recent event recorded in the log appears.
6. To scroll through the event log, press Next or Prev.
NOTE:
Hold down Next or Prev to scroll quickly toward the top or bottom
of the event log.
7.
To exit, press Menu. The display resets to LG 0 (OFF).
8. Press Menu again to exit the User Menu and return to Run/Program
mode.
Month / Day
Time (HH:MM)
Event Type
03/17
15:27
ALE5
Description:
ALERT 5: BOTH LIMITS TRIPPED
NOTE:
Over 300 events can be recorded before the software begins overwriting the existing log history.
The event log is also accessible through S.T.A.R.T. software with the use of a PC laptop and interface cable.
Refer to the
.
LG 0 (OFF)
VIEW EVENT LOG
LG 1 (ON)
VIEW EVENT LOG
03/17 15:27 ALE5
BOTH LIMITS TRIP
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...