Pressure Relief Valve Adjustments
The Pressure Relief Valve governs the maximum system hydraulic
pressure. It is located on the backside of the pump. The pressure relief
valve is factory set and may need to be adjusted depending on the
gate weight.
Pressure relief valve adjustments establish the threshold for the
inherent entrapment sensor (IES). The optimal pressure setting
produces uniform gate travel and trips the IES when the gate
encounters an obstruction.
Adjusting the Pressure Relief Valve
on page
25
and follow the
instructions.
For HySecurity Technical Support contact: 800-321-9947.
Open Valve
The open valve is solenoid operate`d and, when energized, directs the hydraulic flow to open the gate. No
adjustment of this valve is possible or necessary. The black solenoid coil mounts on its valve stem.
HydraSwing Hydraulic Cylinder Maintenance
The hydraulic cylinder requires little maintenance other
than applying NLGI #2 Grade Moly EP (Extreme Pressure)
lithium base grease to zerk fittings at the intervals shown
in the table on the following page.
NOTE:
To apply grease, the gate must be in the Open position.
Fill port
Pressure
relief valve
Open valve
and solenoid
Cylinder end pin
(zerk fitting)
Trunion bearing
(inside base of cylinder)
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...