46
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
i
nStaLLer
m
enu
The Installer Menu options provide more advanced configurations for the gate
operators. Access to the Installer Menu is through the User Menu. The navigational
buttons are the same in both menu modes. Refer to
on
Access:
While a static gate status is being displayed, press the Menu button twice. (Bypasses
the operator status displays.)
When the Close Timer display appears (Hold to Close, if the Close Timer display is
hidden):
1.
Access the Installer Menu
by simultaneously pressing and holding the Reset
and Open buttons.
2.
Release both buttons and the display changes, indicating you have arrived at
the first item in the Installer Menu.
NOTE:
Installer Menu options can also be configured through the use of a laptop
computer and S.T.A.R.T. software. See
Smart Touch Analyze and Retrieve Tool
information found on the HySecurity website
Table 6 describes the Installer Menu items and supplies the factory defaults. (Factory
settings shown in bold.)
t
aBLe
6: i
nStaLLer
m
enu
Installer Menu
Setting Options
Menu Tasks & Explanations
STC Wire
Connections
OT 0
<model name>
0 = Operator Type
1 = SlideDriver (HSG) all models
except 50VF series
2 = SwingRiser (HRG)
3 = HydraLift (HVG)
4 = StrongArm (HTG)
5 = SlideWinder 24
6 = SlideWinder 38
7 = SlideDriver 50VF
8 = StrongArm CRASH
9 = HydraSwing
10 = HydraSupply XL
Select the appropriate number for the
operator.
NOTE:
This menu item only appears if the
Smart Touch Controller is being replaced.
CAUTION: If you are replacing an
STC board, remember to transfer the
operator’s menu settings from the
existing board to the replacement
board. Refer to the installation
instructions that accompany the
replacement STC board.
Not applicable
(N/A)
CT 0 (OFF)
CLOSE TIMER
HYSECURITY
GATE STOPPED
UC 2
USAGE CLASS
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...