Display & Menu Options
MX3636-01 Rev. D
47
Installer Menu
Setting Options
Menu Tasks & Explanations
STC Wire
Connections
AD 0
AC/DC GATE
0 = gate disabled
1 = AC (alternating current)
2 = DC battery-power
3 = HyInverterAC – Power Supply
Usually, power type (AC or DC) is factory
set. Select the type of power that the gate
operator uses and is appropriately wired for.
Not applicable
(N/A)
MN 0
Model Number
0 = model type unknown
1 = HydraSwing 150
2 = HydraSwing 80F
3 = HydraSwing 40 and 40 Twin
4 = HydraSwing 40F
Select the type of HydraSwing model used
at the site.
NOTE:
This menu item only appears when
you replace the STC board or reset the OT
(operator type) using S.T.A.R.T.
N/A
SP 0
SET SPEED
(or indicate Modbus
control)
0 = gate disabled
1 = No ModBus communication**
2 = 2 ft/s
3 = 3 ft/s
**
NOTE:
A setting of 1 indicates no
ModBus communication or wiring is
present. The VFD uses its factory settings
to control speed.
NOTE:
This menu item only appears on the
SlideDriver operator if it is part of the 50VF
series. It does not appear with any other
operator type.
Set the maximum speed for the gate.
CAUTION: Slow Down extended limit
ramps must be installed on the drive
rails!
N/A
UC 0
USAGE CLASS
0 = gate disabled
1 = single family dwelling
2 = multi-family
3 = industrial *
4 = guarded location *
*not serving the general public
Designates the UL 325 Usage Class (UC). The
installer sets the usage class for the operator
to function.
NOTE:
The usage class setting does not
appear on Crash products.
N/A
SH 0
GATE HANDING
0 = gate disabled
R = viewed from the secure side, the gate
moves right to open
L = viewed from the secure side, the gate
moves left to open
NOTE:
Handing only appears on slide gate
operators. On slide gates, the installer sets
the operator’s handing before the operator
will function, so an R or L appears in the
display.
N/A
OP 0
Open Position
0 = gate disabled
R = retracted.
E = extended
HydraSwing only
: The installer must identify
the cylinder’s open position before the
operator will function.
Set OP to R if the cylinder is retracted when
the gate is open.
Set OP to E if the cylinder is fully extended
when the gate is open.
Refer to the
for graphical representations
N/A
BU 0
LOUDEST BUZZER
0 = buzzer not set
1 = Frequency 1 * (on)
2 = Frequency 2 * (on)
*Select the loudest buzzer
Usually, set at the factory. If menu item
appears, select either buzzer 1 or 2. Make
sure to choose the loudest audible buzzer
sound for your operator type.
N/A
FD 0 (OFF)
FACTORY DEFAULTS
0 = user settings
(custom)
1 = reload factory settings
Select setting 1 to return the operator to
factory defaults which globally restores all
menu settings back to new operator status.
NOTE:
If factory defaults are restored,
any customized menu settings will need
to be reprogrammed. You can save your
customized menu settings using a PC laptop
& S.T.A.R.T.
N/A
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...