If standard 11-pin box type vehicle detectors are to be used, perform the following procedure.
If there is sufficient space, install the sockets in the control box; if not, then install them in a separate external
housing. Carefully consider your peripheral connections. Any peripheral device required for safe gate
operation should be attached to 24VDC in case of an AC power outage.
NOTE:
Box detectors with relays require five times more power than Hy5x detectors. One Hy5x detector draws about 0.005A.
Consider Hy5x vehicle detectors for DC and Solar powered sites.
1. Connect 24 Volt power to the detector. Connect Pin No. 1 to a 24VAC or 24VDC terminal and Pin No. 2
to common.
2. Connect output Pin No. 6 to the Common Bus and output Pin No. 5 to one of the four detector
terminal inputs (depending upon the detector function required) on the Smart Touch Controller.
If multiple detectors are used, route the power wires and common wire from socket to socket (daisy-chaining)
rather than individually running each wire to the same location. The only wires that are separate are the output
wire to the Smart Touch Controller and the detector loop input wires.
Always keep the detector loop wires well twisted beyond the area of the loop. The lead in portion sealed in a
saw cut does not need to be twisted so long as the wires are encapsulated in loop sealant and cannot move.
24V A
C Acce
ssory po
wer
+ 24V
DC
COMM
ON
VEHICLE LOOP
Loop
Detector
To LOOP terminal on Smart
Touch Controller
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
1
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR
COM
DO NOT USE
SENSOR 2
DO NOT USE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
LOCK INTERLOCK
EMERG CLOSE
FIRE DEPT OPEN
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
RADIO OPTIONS
DRIVE
POWER
RS485
MO
TOR
USER 1
USER 2
USER 3
VEHI
CLE DETE
CT
OR
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
STOP
/BUZZER
FREE
EXIT
INSIDE
OB
STR
OUT
SIDE
OB
STR
SHADO
W
RE
SET
WIE
GAND
Hy
Security
COM
NO
MX000585
VERSION
S/N
RS232
DISPLA
Y
VEHI
CLE DETE
CT
OR
COM
COM
A
B
RPM
COM
OPEN
S 1
+24V
+24V
STATUS
LED
Pin 1
Pin 2
NOTE:
Both 24 Volts AC and DC are available, so either detector voltage may be used.
24 VAC is not available if the Gate Operator is equipped with the UPS option. 24 VAC is
available at the spade terminals on the lower left corner of our power supply (marked
ACC); 24 VDC is available from the Common and the +24 V spade terminals.
Power Supply
Module
CAUTION
Match detector connection to its
voltage rating (24VAC or 24VDC).
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...