Make sure all users of the gate know where the emergency stop
button is located (see illustration). It complies with UL 325 Safety
Standards requirements.
Pressing the emergency stop button while the gate is opening or
closing disables the automatic close timer and stops gate travel.
Gate travel remains stopped until the operator receives another
open or close signal.
m
anuaL
r
eLeaSe
O
ptiOn
WARNING
Before attempting a manual release, make sure the gate is not in motion and power is disconnected
(turned OFF)
.
The manual release option can be found on the brake manifold.
To move the gate manually, turn OFF the power switch on the control box in the HydraSupply cabinet, and
then simply push the release lever, as shown in the illustration.
Emergency Stop
button
HydraSupply
Closed position
Manual Release
Open position
Brake manifold
HydraSwing 40, 40F, and 40 & 40F Twin
CAUTION
For the HydraSwing 80F or 150 models, pushing
close while using the manual release option may
cause an air pocket to form in the hydraulic
cylinder and cause overflow from the reservoir.
If you notice fluid leakage, stop gate travel
immediately and use the hand pump.
© 2018
Safety
MX3636-01 Rev. D
9
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...