A state-of-the-art position sensor is enclosed within the cylinder
housing so the maintenance of physical limit switches is
eliminated and the durability of the operator is enhanced. The
operator senses the gate position and communicates to the
Smart Touch Controller. The Learn Close Limit display appears
when power is initially supplied to the operator.
When set, position sensing remains intact even if power is lost.
The only exceptions occur when factory defaults are reinstated,
or the Smart Touch Controller is replaced.
S
ettinG
tHe
c
LOSe
& O
pen
L
imitS
Programming the limit settings is usually a one-time occurrence. The Reset and Program buttons do not
function while the operator is learning its limits. More information about relearning limits is found in Learn Limit
Reset in the Installer Menu. Refer to
To establish the open and close limits, follow the steps in the chart below, and then cycle the gate a few times.
LEARN CLOSE
INCHES: - XXX.X
Learn Close Limits
Choose one of the following bullet procedures depending on the gate location.
•
The gate is in the desired closed position
– press
Stop
twice. The buzzer chirps twice and
the full close stop is retained in memory.
•
The gate is not in the desired closed position
- press and hold the
Close
button until the
gate moves to full close. (Flashing numbers decrease while the gate is closing.) If you need
to reverse the angle of the closed gate, press and hold
Open
to for a second or two. Release
the button. To retain the closed position press
Stop
twice. The buzzer chirps twice and the
full close stop setting is retained in memory.
LEARN OPEN
INCHES: + XXX.X
Learn Open Limits
Press and hold the
Open
button until the gate reaches the open position you desire. Release
the
Open
button. If the gate needs adjustment, you can press and hold
Close
to reverse
direction.
Press
Stop
twice to preserve the open stop location in memory. The buzzer chirps twice and the
full open stop setting is retained in memory.
To reset the close and open limits, refer to page 54.
24
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...