HySecurity gate operators use software to control gate movement, contacts, and accessories. The changeover
in 2016 to monitoring sensors has been a simple process.
• Build Year is a new Installer Menu item in the Smart Touch Controllers versions h4.50 (and higher).
•
New labels show where Edge, Photo Eye Open and Photo Eye Closed have changed to “SENSOR”
inputs. You can program the type of sensor wired to one of those inputs. See table below.
• Installer Menu items, PC and GC (Photo eye output and edge sensor output) which used to default
to Normally Open (NO) have been converted to Normally Closed (NC) contacts so the software can
detect the presence and proper operation of external entrapment protection sensors.
Table 3: Changes to Sensor Inputs on the Controller
Location of Sensor Inputs on Controller
Installer Menu Item Codes
Smart Touch Controller (STC): Hydraulic gate operators
Smart Touch Display:
Input #
Current Silk Screen Label
2016 Silk Screen
Label
OLED - two line,
32 character
LCD - 7
segment text
13
EDGE SENSOR
SENSOR 1
S1 SENSOR 1
S1
17
PHOTO EYE OPEN DIRECTION
SENSOR 2
S2 SENSOR 2
S2
19
PHOTO EYE CLOSE DIRECTION
SENSOR 3
S3 SENSOR 3
S3
NOTE:
Three inputs for external entrapment protection sensors are available on the HySecurity gate operator controller. New silk
screen controller boards are on order, but until they are ready for shipment, labels will be overlaid on the board to indicate
terminology adaptations.
Table 3 indicates how the edge and photo eye inputs have been renamed to generic “sensor” inputs. They are
interchangeable and configurable. The software must know what type of sensor is wired to SENSOR 1, 2, and 3
BEFORE
it will allow gate travel.
e
xternaL
e
ntrapment
p
rOtectiOn
S
enSOrS
:
w
Hat
tHe
i
nStaLLer
n
eedS
tO
d
O
NOTE:
All HySecurity gate operators, indicating a manufacturing date of 2016 in the serial number, will have the Build Year set to 2.
A Build Year of 2 (BY 2) indicates that your gate operator is prepared to monitor for external entrapment protection sensors. The
Build Year setting appears in the system scroll on the gate operator display.
The gate operator will not automatically cycle
the gate unless an indication that the appropriate number of external entrapment protection sensors are connected and
operational.
The normally closed (NC) entrapment protection sensors wired to the Controller’s SENSOR inputs are
monitored using HySecurity software. Prompts appear in the display requesting specific configurations based
on the gate operator type.
Table 4: Installer Menu Settings for SENSOR Inputs
illustrates what options are available for the HySecurity
Controller’s configurable inputs. Inputs labeling changed to:
SENSOR 1
SENSOR 2
SENSOR 3
SENSOR COM
.
© 2018
Entrapment Protection
MX3636-01 Rev. D
31
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...