S
uppLy
p
Ower
tO
tHe
S
enSOrS
CAUTION
All external entrapment protection sensors must be wired to the SENSOR COM terminal for monitoring purposes.
Review sensor wiring diagrams found in
Wiring HySecurity Sensors: Smart Touch
Until the gate operator receives a command to run (open or close command), the sensors are not receiving
power. However, to
temporarily
power sensors and check that the gate operator is monitoring the sensors
properly, turn on Photo Eye Align mode.
To turn on Photo Eye Align mode, take the following steps:
1. Access the User Menu and select PE. (Press the Menu button twice to access the User Menu. See chart
on the previous page.)
2. Press NEXT and continue to press NEXT until PE 0 (OFF) appears.
3. Press SELECT.
PE characters begin blinking.
4. To turn ON photo eye alignment and temporarily power the sensors, press NEXT so PE 1 (ON) appears.
5. Press SELECT.
PE stops blinking.
6. Press MENU to exit Menu Mode and return to Run Mode.
NOTE:
The Photo Eye Align mode turns OFF with the next limit contact. For more information, refer to
Controller
Temporarily apply Power to Sensors
LED Status
Smart Touch
(Hydraulic gate
operators)
PE 1 (ON)
PHOTO EYE ALIGN
LEDs next to the sensor connections will be lit when no power
is being applied. When PE is turned ON, the LEDs turn off. If
they do not turn off, check for wiring issues such as a short or
misapplied relay COM connections. See CAUTION on page
33.
Smart DC
(electromechanical
gate operators)
PE 1 (ON)
PHOTO EYE ALIGN
When PE is ON, the LEDs associated with the sensor devices
will be lit if the sensors are properly connected and sensors
are grounded. The LEDs turn off when the ground circuit is
removed.
PE 1 (ON)
PHOTO EYE ALIGN
PE 1 (ON)
PHOTO EYE ALIGN
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
34
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...