38
MX3636-01 Rev. D
HydraSwing Programming & Operations
© 2018
i
nitiaL
S
etup
Once you have completed the installation of the HySecurity operator and attached the wired accessories,
you’re ready to program the operator. Two different approaches exist:
•
Connect a laptop computer to the serial RS-232 connector and set the operator menu configurations
via the S.T.A.R.T. software. Refer to the
.
NOTICE:
Use a laptop computer at your place of business to conveniently download the free START software
before heading out into the field. This makes it easy to adjust and configure operator settings using a laptop in
the field.
• Manually navigate through the User and Installer Menus using the four Menu Mode buttons located on
the Smart Touch Controller Keypad. The instructions for performing this second option are provided in
this section.
After installing a new operator, an initial sequence of set up prompts appears when you first turn ON the
Control Box power switch. You need to answer the prompts before the gate operator will run. The operator is
in “MENU” mode.
For example:
In the HydraSwing operator, you must set usage class and address 3
sensor inputs.
UC =
Usage Class
. Set the usage class to 1, 2, 3, or 4 depending on
the site.
Four different vehicular usage classes are defined by UL 325.
Information about the classes can be found online through DASMA
or UL 325
OP = Open Position. E = Extended cylinder and R = Retracted cylinder. Refer to
S1, S2, and S3 = Contact and non-contact external entrapment protection sensor inputs that may require
monitoring per installation site and UL 325 Standard of Safety requirements.
For more information, refer to
UL 325 - 2016 Monitored Entrapment Wiring Diagrams
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
1
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR
COMMON
DO NOT USE
SENSOR 2
DO NOT USE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
LOCK INTERLOCK
EMERG CLOSE
FIRE DEPT OPEN
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
RADIO OPTIONS
DRIVE
POWER
RS485
MO
TOR
USER 1
USER 2
USER 3
VEHI
CLE DETE
CT
OR
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
STOP
/B
UZZER
FREE
EXIT
INSIDE
OB
STR
OUT
SIDE
OB
STR
SHADO
W
RE
SET
WI
EGAND
Hy
Security
COM
NO
MX000585
VERSION
S/N
RS
232
DISPLA
Y
VEHICLE DETE
CT
OR
COM
COM
A
B
RPM
COM
OPEN
EDGE
+24V
+24V
STATUS
LED
Power switch on a
HydraSwing control box
UC 2
USAGE CLASS
S3 1 (NOT USED)
SENSOR #3 TYPE
Selection: Usage Class
Select between: 1,2,3, or 4
SENSOR settings required
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...