The following chart describes a few of the scrolling status displays that may appear in your gate operator.
Operator Status Display
Variables
Description
Build Year
Indicates whether the gate operator was
manufactured before or after UL 325 -
2016 Safety of Standard changes that
require monitoring of external entrapment
sensors.
All gate operators manufactured in 2016
or later will show Build Year - Post 2016
because it contains software version h4.50.
If you plan to upload 4.50 software (or
later) into your gate operator, you will need
to set the appropriate build year according
to the date of manufacture.
Dual Gate or Sequenced Gate
This display only appears when the
operator is used in interlocked or
sequenced gate systems and indicates
the function of the operator. Refer to
Bi-Parting & Dual Gate Systems
on
.
Indicates, in an interlocked or dual gate
setting, whether the operator is set to
Primary or Secondary or Sequenced Gate
Configuration). The setting is assigned in
the Installer Menu.
Operator Type (OT)
1 = SlideDriver (HSG) all models
except 50VF series
2 = SwingRiser (HRG)
3 = HydraLift (HVG)
4 = StrongArm (HTG)
5 = SlideWinder 24
6 = SlideWinder 38
7 = SlideDriver 50VF
8 = StrongArm CRASH
9 = HydraSwing
10 = HydraSupply XL
Indicates and identifies the operator.
Model Number (MN)
0 = Model type unknown
1 = HydraSwing 150
2 = HydraSwing 80F
3 = HydraSwing 40 and 40 Twin
4 = HydraSwing 40F
Identifies the HydraSwing model.
Open Position (OP)
R = Retracted and E = Extended
Indicates position of cylinder when the
gate is fully open.
Usage Class (UC)
1, 2, 3, or 4
Displays the operator’s Usage Class
designation per UL 325 standards.
Input Voltage VDC
The number varies depending on the
voltage that the power board is providing.
Input voltage (DC Buss voltage) to the
STC is shown. Helps to determine proper
power connections.
Cycle Count (CC)
One cycle equals a full open and close
sequence. Partial cycles are not counted
Displays the number of cycles the gate
operator has incurred. Similar to an
odometer, it resets to zero after 999,999
cycles.
Close Timer (CT)
The first menu item in the User Menu.
NOTE:
You can also access the Installer
Menu from this display.
Displays the number of seconds before the
open gate initiates.
Stop the Status Display Scrolling
To stop the operator status display scroll and focus on one item, press Select. Press Select a second time, to
resume the scrolling display.
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...