Display & Menu Options
MX3636-01 Rev. D
53
Installer Menu
Setting Options
Menu Tasks & Explanations
STC Wire
Connections
ID 0 HYINVERTER
DIAGNOSTICS
0 = no diagnostics displayed
1 = view diagnostics displays
HYINVERTER INPUT - LINE xxx.x VAC
HYINVERTER TEMP - xxx.xF / xxx.x C
HYINVERTER VOLTS - BATTERY xx.x
VDC HYINVERTER - BATTERY xxx.x %
Controls which system diagnostics appear
on the display. With a setting of 1, you can
access the AC Power Supply with HyInverter
AC diagnostic mode. Use the Next or
Previous buttons, on the gate operator’s
keypad, to view the diagnostics on the STC
display.
NOTE:
These same diagnostics appear on
the AC Power Supply with HyInverter AC
display in a constant scrolling format.
AC Power Supply
with HyInverter
AC to STC
(Modbus RTU
communication
protocol via
RS-485.)
ELD0 RUN MODE
EXIT LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the Hy5B Free Exit loop detector.
Hy5B
ILD0 RUN MODE
IND OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the Hy5B Inside Obstruction Loop
detector.
Hy5B
OLD0 RUN MODE
OUT OBS LOOP SET
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the Hy5B Outside Obstruction Loop
detector.
Hy5B
SLD0 RUN MODE
SHADOW LOOP SET
(Reset Loop Set)
0 = Run mode
1 = Show frequency
2 = Show call level 0-7
3 = Set Frequency
Controls the Hy5B Shadow/Reset Loop
detector.
Hy5B
a
djuStinG
tHe
G
ate
S
peed
The gate speed designates how quickly the gate opens or closes. The available range varies dependent on the
model number. Refer to the chart below.
Two Installer Menu settings, one for OPEN SPEED and one for CLOSE SPEED, can be accessed from the Smart
Touch Controller’s display. The steps involved in changing the open speed (OS) are shown below. The steps to
set the close speed are the same, except you must access the close speed menu item (CS).
HydraSwing
Model
Approximate Speed Settings
150
1
1 = 30s, 2 = 25s, 3 = 20s
80F
2
1 = 25s, 2 = 20s, 3 = 15s
40
3
1 = 20s, 2 = 17.5s, 3 = 15s
40F
4
1 = 15s, 2 = 12.5s, 3 = 10s
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...