STC Inputs & Wiring
MX3654-01 Rev. D
59
i
nteGratinG
witH
S
ecurity
S
yStemS
and
H
y
n
et
™ G
ateway
HySecurity hydraulic gate operators provides a 2-wire, serial interface (RS-485 connection) which allows remote
access to one or more operators. With software protocols provided by HySecurity, bi-directional status updates
and control commands are easily integrated with a central controller (computer or server), which becomes
the primary (master) to the connected operators. Up to 31 physical operators can be polled from the central
master command station. Reset requests, gate control, gate status, and gate faults can be monitored and
information can be retrieved from the central command station.
The RS-485 interface is also used to communicate with the HyNet Gateway, a web-enabled interface. To view
the user guide and quick start information regarding HyNet Gateway SFP 4/1, go to the HySecurity website,
Technical_Support_Installation_Manuals.
SA 1
SYSTEM ADDRESS
SA Display in the
Installer Menu
NOTE:
Connect HyNet power to +24VDC on the
Power Supply Board. Do NOT connect HyNet to
+24V terminal under RADIO OPTIONS.
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
1
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR COM
DO NOT USE
DO NOT USE
DO NOT USE
CHARGER
AC LOSS
LOCK INTERLOCK
EMERG CLOSE
FIRE DEPT OPEN
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
RADIO OPTIONS
DRIVE
POWER
RS485
MO
TOR
USER 1
USER 2
USER 3
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
VEHICLE DETE
CT
OR
ST
OP
/B
UZZER
FREE
EXIT
INSIDE
OBS
TR
OUT
SIDE
OBS
TR
SHADO
W
RE
SET
WI
EGAND
Hy
Security
COM
NO
MX000585
VERSION
S/N
RS232
DISPLA
Y
VEHICLE DETE
CT
OR
COM
COM
A
B
RPM
COM
OPEN
S 1
+24V
+24V
STATUS
LED
24V A
C Ac
cessor
y pow
er
+ 24
V D
C
COM
MO
N
+ 24VDC
Inputs
SENSOR 2
SENSOR 3
Once the physical connection is made and protocols are established,
an SA (System Address) must be assigned for each operator through its
Installer Menu. For network communication, choosing a “SA” of 1 to 99
establishes individual network polling addresses. A “SA” of zero means
no network communication is desired.
If you plan to connect operators to a networked central master
command station, contact HySecurity for software protocols and
additional information. Refer to
Contact Information on page 2.
RS-485
Connector
HyNet
Wire
Harness
Flying Lead connects to +24V
COMMON
terminals
+24V
Summary of Contents for HSG80F
Page 2: ...www SecureOpeners com 800 878 7829 Sales SecureOpeners com...
Page 14: ...Page intentionally left blank xiv MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 36: ...Page intentionally left blank 22 MX3636 01 Rev D HydraSwing Programming Operations 2018...
Page 124: ...110 MX3636 01 Rev D HydraSwing Programming Operations 2018 Page intentionally left blank...
Page 136: ...122 MX3636 01 Rev D HydraSwing Programming Operations 2018...