7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
35
MX4514 Rev. A ©2019
www.hysecurity.com • 800-321-9947
6. Push and hold the OPEN button on Control Board until gate reaches the fully intended open position.
7. OPEN LIMIT ADJUST
:
• If gate opens to left (viewing from secure side), adjust left hand knob of limit assembly (IMAGE 17-
5) until the GREEN LED illuminates on control board (IMAGE 17-4).
• If gate opens to right (viewing from secure side), adjust right hand knob of limit assembly (IMAGE
17-5) until the GREEN LED illuminates on control board (IMAGE 17-4).
8. Push and hold the CLOSE button on Control Board until gate reaches the fully intended close position.
9. CLOSE LIMIT ADJUST
:
• If gate closes to left (viewing from secure side), adjust left hand knob of limit assembly (IMAGE 17-
5) until the RED LED illuminates on control board (IMAGE 17-4).
16: GATE LIMIT LEARNING PROCEDURE (CONT.)
(Continued)
LEFT MOVEMENT ADJUST
LIMIT KNOBS
LEFT
MOVEMENT
ADJUST
KNOB
RIGHT
MOVEMENT
ADJUST
KNOB
RIGHT MOVEMENT ADJUST
MORE
TRAVEL
LEFT
LESS
TRAVEL
RIGHT
LESS
TRAVEL
RIGHT
LESS
TRAVEL
LEFT
LESS
TRAVEL
LEFT
MORE
TRAVEL
RIGHT
MORE
TRAVEL
RIGHT
MORE
TRAVEL
LEFT
IMAGE 17-5:
GATE LIMIT ASSEMBLY ADJUSTMENT - GATE DIRECTION
NOTES:
If the wrong limit LED lights (i.e.
the close LED lights when gate at
open limit), reverse the limit wires
(reverse orange and white) on the
motor motor connector.
If a gate moves in opposite
direction from what is expected,
reverse the motor power lead
wiring (red & black wires) for that
motor.