7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
55
MX4514 Rev. A ©2019
www.hysecurity.com • 800-321-9947
FUNCTION BUTTON / Adv. Settings
FUNCTION
9. Adv. Settings
Language
English
Language
English
(blink)
Clock
24H
(blinking)
Clock
24H
Contrast
100%
(blinking)
Contrast
100%
Direction Motor
->
Auto Close Opt.
On
Exit Opt.
Off
Anti-Tailgate
Off
Photo Test
Off
Photo Test
Off
(blinking)
Anti-tailgate
Off
(blinking)
Inputs
Photo
Inputs
Photo
(blinking)
Auto Close Opt.
On
(blinking)
Exit Opt.
Off
(blinking)
Direction Motor
->
(blinking)
12 Hour
English
0%
Off
Off
Off
Off
Photo
<-
24 Hour
English
100%
On
On
On
On
Loop
->
10. Default (see next page)
8. Standby (see previous page
UL Input
(See next page)
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
FUNCTION>ADVANCE SETTINGS MENU:
• LANGUAGE:
English only
• CLOCK:
Select 12H or 24H clock.
• CONTRAST:
Do not set below 20%.
• DIRECTION MOTOR:
Changes main
motor direction (Can only be performed in
learn mode). Only used on 24V commercial
operators.
• AUTO CLOSE OPTION:
Allows auto close
timer to close from any open position.
• EXIT OPTION:
Disables free exit input
when partially open.
• ANTI-TAILGATE:
Closes gate
immediately after vehicle has cleared
safety sensors.
• PHOTO TEST:
Factory use only.
• INPUTS:
Select LOOP or PHOTO.
(Continued on next page)
NOTES:
•
Turning contrast down to less than 20% may
make display unreadable.
•
Motor direction adjustable only in Learn
Mode.