7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
63
MX4514 Rev. A ©2019
www.hysecurity.com • 800-321-9947
PIN 12 = LAMP
PIN 13 = GND (Ground)
PIN 14 = ALARM
PIN 15 = GND (Ground)
PIN 20 = +24VDC Regulated
PIN 21 = GND (Ground)
LAMP (12-13):
•
Provides fused power (1.85A max) to drive a flashing warning lamp to indicate gate operation.
•
This output is active when the gate is operating (Opening and Closing).
•
Lamp Delay sets the amount of time the lamp accessory output is activated prior to gate movement. Settings
from 0 to 5 seconds with a step of 0.5 seconds.
ALARM (14-15):
•
Provides fused power (0.5A @ 12VDC) to drive an alarm siren to signal the occurrence of a hard shutdown,
caused by 2 consecutive entrapment events (signals).
•
This alarm output is reset by pressing the “Reset Hard Shutdown” button on the front panel or activating the
“FIRE” input.
24VDC POWER OUTPUT (20-21):
•
This power output is located along the lower strip of input connectors at pins 20 and 21.
•
Pin 20 outputs a +24 Volts DC current, which is regulated and turns off when the control board goes into sleep
mode (power saving mode).
•
This output may be used to power accessories that are required to power-down when board enters power
saving mode. This is primarily beneficial for solar powered configurations where it is desirable to reduce
power consumption.