7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
71
MX4514 Rev. A ©2019
www.hysecurity.com • 800-321-9947
MAINTENANCE SCHEDULE
Component
Maintenance Action
6
Months
Annually
ALARM
Activate the primary (inherent) reverse system
by blocking the gate with a solid object. The
gate should reverse momentarily then stop.
Restart the gate and block again with a solid
object. The gate should reverse momentarily,
then stop, and go into hard shutdown with an
alarm.
x
x
BACKUP
SYSTEM
If operator is equipped with option DC backup
system, check to be sure the system opens the
gate upon loss of AC power.
x
x
BATTERY
If operator is equipped with option DC backup
system, check the batteries for any leakage or
loose connections. Batteries should be replaced
every two years.
x
x
FIRE DEPT
Check emergency vehicle access device for
proper operation.
x
x
GATE
Inspect for damage.
x
LOOP(S)
Check vehicular reverse and shadow loops for
proper operation.
x
x
RELEASE
Check manual release for proper operation.
x
x
MOUNTING
HARDWARE
Check screws and nuts.
x
PHOTO EYES
Use a hand held cylinder (approx. 2” [5cm]
diameter and 12” [30cm] in length) and pass
between photo eye line of sight. Pass cylinder
through line of sight near transmitter, pass
cylinder through line of sight near receiver, pass
cylinder through line of sight halfway between
transmitter and receiver. Gate should stop
and reverse on detection. Check for humidity,
oxidation, and foreign bodies (such as insects)
and remove from chassis. Clean housings
and front plate. Do not use alcohol, benzene,
abrasives or other cleaning products. Use
only a slightly dampened soft cloth to clean
transmissive panels or lenses.
x
x
18.1 MAINTENANCE SCHEDULE