2
© 2012 Installation and Reference Manual D0125 Rev. H
Features
High Speed, Very Heavy: SlideDriver 50VF2, 50VF2-EFO, and 50VF3
UL class III & IV.
These operators are designed for very heavy, up to 5,000 lbs gates moving at high and very high speeds.
The variable frequency drive moves very heavy gates at the following speeds:
26 inches per second, 50VF2
26 inches per second, 50VF2 – EFO (36in/s Emergency Fast Operate to close on a constant HOLD command.)
36 inches per second, 50VF3
SlideDriver VF models close gates to a very precise point and are extremely easy on gate hardware. SlideDriver
VF operators use a variable frequency drive, larger wheels and a higher flow rate pump to reach 2 to 3 inches
per second. These operators use the same powerful HySecurity Smart Touch controller and simple and reliable
hydraulics of all SlideDriver models.
The Smart Touch Controller
This is the brain of HySecurity operators. Groundbreaking technology combined with sturdy construction to
reliably serve in the harshest environments. The Smart Touch Controller can quickly be configured by an
installer or user to adapt to nearly any site specific functional requirement. All system settings are performed
with the use of four programming buttons and an LCD display. The Smart Touch Controller has no switches to
set. An RS232 port for external communication is standard. An EEPROM records date stamped system events.
A log of events can be downloaded from the RS232 port to a laptop computer to evaluate abnormal gate system
operation. HySecurity HY-5A vehicle detectors set a new industry standard by communicating valuable
performance data to the Smart Touch controller, allowing quick and deep, user-friendly diagnostics.
SlideDriver C, Correctional Facility
(-C)
The CF models offer an extra heavy 10-gauge cover with three different locking options. Correctional
Facility operators are shipped ready to interface to the many options and interlocks commonly used at
correctional facilities, such as gate position outputs, interlock capability for sally ports and an interface
relay to control an external solenoid lock.
SlideDriver M, Modular
(-M)
This family of operators is a two part modular version of the standard SlideDriver operator. The motor,
hydraulic pump and electric controls are located in a separate enclosure, often at a distance from the
drive unit. This version allows for a more flexible placement of the operator, which may be required or
desirable in some situations involving unique mounting, special security (including blast mitigation) or
those areas requiring a very quiet operator.
Stopping the Gate
All models employ a time delay
soft stop
system. Additionally, brake valves are used to control the
stopping of heavy or fast moving gates. These valves are exclusive to HySecurity operators. They are
independently adjustable to allow the gate to stop predictably and without banging.
Starting the Gate
The variable speed drive provides a
soft start
which accommodates for the load and starts the gate
smoothly, similar to letting your foot slowly off a car clutch without any lurching.
WARNING:
DO NOT attempt to connect to 110/120V power. The variable frequency (VF) drive
SlideDriver 50VF2, 50VF2-EFO, and 50VF3 operators can only be connected to 208V, 230V single- and
three-phase power supplies or 460V three-phase power supplies. Refer to the
Wire Chart
on page 59 for
proper wire sizing and the distances they accommodate. See further WARNINGS on page 60.
Summary of Contents for SlideDriver 50VF2
Page 2: ......
Page 28: ...14 2012 Installation and Reference Manual D0125 Rev H Section 2 Technical Drawings...
Page 29: ...15 2012 Installation and Reference Manual D0125 Rev H Section 2 Technical Drawings...
Page 36: ...22 2012 Installation and Reference Manual D0125 Rev H Section 3 Wiring Control Inputs...
Page 63: ...49 2012 Installation and Reference Manual D0125 Rev H Section 6 Internal Solenoid Lock Drawing...
Page 64: ...50 2012 Installation and Reference Manual D0125 Rev H Section 6 Internal Solenoid Lock Drawing...
Page 81: ...68 2012 Installation and Reference Manual D0125 Rev H...