19
© 2012 Installation and Reference Manual D0125 Rev. H
Section 3
— Setting Operator Usage Class and Handing
NOTE:
Make sure the hydraulic hoses are connected
properly to the quick disconnect fittings on the manifold. A
label near the connection point describes this procedure. If
the hoses are connected incorrectly, the gate will run
backwards (close when the OPEN button is pressed) and
this may trigger an error [
] on the display. If this occurs,
the hoses need to be reconnected properly and the RESET
button must be pressed to reset the operator).
1. Turn the power switch ON. The operator status displays scroll past. The
display directly enters the Installer Menu and the usage class [
] menu
item appears.
NOTE
: If the operator has been configured, the Installer Menu must be
accessed in order to reach the system configuration menu items. See steps
3c and 3d on page 18.
2. While the usage class [
is being displayed), set the user class as
defined by UL. Press SELECT, and then press NEXT to choose
between [
] or [
]. See page 33 for UL usage class definitions.
Refer to page 18 for a reminder on how to use the Menu Mode buttons.
3. When the appropriate usage class is displayed, press SELECT to accept
it. The characters on the display stop blinking.
NOTE:
The Installer Menu cannot be exited and the operator will not
function until the selection for usage class and gate handing have been
entered.
4. To set the gate “hand,” press the NEXT button. The handing menu item
appears [
]. Press SELECT, and then press NEXT to choose
between “
” for right hand or “
” for a left-hand gate opening.
5. When the appropriate handing is displayed, press SELECT to accept it.
NOTE
: Never disconnect the limit switch wires from the Smart Touch
Controller or rearrange the limit switch hardware on the chassis to affect
the handing of the gate.
6. At this point, you should exit the Installer Menu by pressing the
PROGRAM button. The display jumps to the Close Timer [
] setting
in the User Menu, Either set the Close Timer by the same programming
sequence described on the previous page or press the PROGRAM
button again to exit to Run Mode.
7. Test for proper handing by observing which way the wheels rotate. With
the wheels unclamped, cycle the gate open and close. Use the OPEN
and CLOSE buttons on the keypad. Note wheel rotation to verify proper
gate handing. If the wheels are rotating opposite from the direction you wish the gate to move, return to the gate
handing display and correct gate handing.
NOTE
: Since the wheels are unclamped, neither limit switch should trigger at the start of this test. After ten seconds,
the
alert may appear because the system did not sense gate motion. This is a “normal” alert and can be reset
when you complete the test.
8. Re-clamp the wheels and, if necessary, press RESET to clear the alert status.
To change handing
connect hoses
according to the
label on the pump
pack.
Summary of Contents for SlideDriver 50VF2
Page 2: ......
Page 28: ...14 2012 Installation and Reference Manual D0125 Rev H Section 2 Technical Drawings...
Page 29: ...15 2012 Installation and Reference Manual D0125 Rev H Section 2 Technical Drawings...
Page 36: ...22 2012 Installation and Reference Manual D0125 Rev H Section 3 Wiring Control Inputs...
Page 63: ...49 2012 Installation and Reference Manual D0125 Rev H Section 6 Internal Solenoid Lock Drawing...
Page 64: ...50 2012 Installation and Reference Manual D0125 Rev H Section 6 Internal Solenoid Lock Drawing...
Page 81: ...68 2012 Installation and Reference Manual D0125 Rev H...