Smart DC Controller

6

 

  D0719 Rev. C 

HyNet Attachment Kit: MX3867 

  

©

 2016  www.hysecurity.com

COM

COM

COM

COM

COM

COM

COM
COM

STOP
OPEN

RADIO

CLOSE

OPEN

OPEN

PARTIAL
SENSOR 2

EXIT 

LOOP
BLOCK

EXIT

IN  OBS

LOOP

OUT OBS

LOOP

CENTER

LOOP

COM
+ 24 V
EMERG

OPEN

SHOW

LEDs

RADIO OPTIONS

EDGE

+24V

OPEN

COM

DUAL  GATE

COM

B

A

U

SE

R2

COM NO

DC

COMMON 

TERMINALS

 

24VDC

24VDC

12VDC

12VDC

SENSOR 3

SENSOR 1
SENSOR 

SA 0 (OFF)

SYSTEM ADDRESS

Press Select again to set gate 

operator's system address 

(Each gate operator attached 

 

to the same HyNet must have 

 

a unique SA number. Choose 

 

1, 2, 3, or 4.)

2

1

To access Installer Menu, press 
Menu button twice. Then, press 
Reset and Open.

Press Select to navigate to 
Installer Menu item "SA" 

 

System Address.

3

To exit Menu mode, press Menu. The 
gate operator returns to Run mode.

4

Refer to 

Table 1: HyNet LED Indicators

 on page 2. 

Solid green means serial communication is active and 

functioning well.

HySecurity gate operators provide a 2-wire, serial interface (RS-485 connection) which allows remote access to 
one or more operators.

When the physical connection is made and protocols are established, an SA (System Address) must be assigned 
for each operator through its Installer Menu. 

For network communication, choosing a “SA” of 1 to 4 establishes individual network polling addresses. HyNet 
only utilizes numbers 1, 2, 3, or 4.

A “SA” of zero means no network communication is desired.

SA  1    

SYSTEM  ADDRESS

OPEN

CLOSE

STOP

MENU

RESET

PREV

NEXT

SELECT

5

For IP network setup, refer to the HyNet Quick Start 
manual supplied in the HyNet box.

Summary of Contents for StrongArmPack DCS 10

Page 1: ...ArmPark DCS 14 This document is a supplemental document that provides specific information regarding configuration of the HySecurity gate operator with installation and wiring of the HyNet Gateway For...

Page 2: ...ommunication is established between gate operator and HyNet 2 RED steady Gate operator network communication is not configured or established 2 RED flashing HyNet is attempting to connect to network w...

Page 3: ...HyNet Assembly Velcro strip Peel off protective layer and adhere Velcro strip to HyNet mounting plate Alcohol wipe Use alcohol wipe to clean mounting plate surface before applying Velcro adhesive back...

Page 4: ...5 6 Replace and secure covers 2 Peel protective paper off Velcro strip 3 Adhere the Velcro strip to the inside portion of the StrongArmPark DC chassis Press firmly NOTE Recommended HyNet location is...

Page 5: ...DC Controller pin layout changed a few years ago On controllers with part numbers marked MX001457 and MX3037 Revisions A B and C be sure you re connecting the flying lead to the 24V spade located unde...

Page 6: ...gate to Installer Menu item SA System Address 3 To exit Menu mode press Menu The gate operator returns to Run mode 4 Refer to Table 1 HyNet LED Indicators on page 2 Solid green means serial communicat...

Page 7: ...__________ Phone contact number ____________________________________ Checked Initials 1 Site Planning ______________ RJ 45 cable to system network 2 Safety ______________ Review Important Safety Infor...

Page 8: ...8 D0719 Rev C HyNet Attachment Kit MX3867 2016 www hysecurity com...

Reviews: