RUN MODE
The Run Mode displays appear static when the
operator is ready and waiting for a run command.
When the display is flashing “GATE OPENING”
or “GATE CLOSING”, a command has been
received and the gate is in motion. The command
may come from a variety of sources: a card reader,
push-button remote, or recognition of a vehicle
passing over a loop detector. In all cases, the
operator “runs” the motor when it receives an
operational command.
Three displays indicate the position or status of the
gate. The keypad entry used to access the User or
Installer menus, begins at one of these Run Mode
displays. See Figure 32
.
Figure 32. Run Mode Displays
NOTICE
To access the User or Installer menus, the
motor cannot be engaged and the gate cannot
be moving.
HYSECURITY
GATE STOPPED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE OPEN
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
Pressing Open, Close, or Stop causes the
gate to perform the command.
Pressing Reset clears alerts or faults and
returns to Run Mode.
NOTE:
Press Reset at any Run mode
status display to view the software version.
For example: h5.57
Pressing Menu scrolls through operator
status displays and accesses the User Menu.
Note:
Pressing the MENU button twice,
bypasses the operator status displays.
VIEWING OPERATOR STATUS DISPLAYS
Press the MENU button once and the operator
status displays appear in two second intervals.
Pertinent information appears to provide a quick
overview of the operator’s status or configurations.
See
Figure 33.The type of information that may
scroll across the display includes: software version,
operator type (OT), gate handing (LEFT HAND
or RIGHT HAND), buss voltage, and life cycle
counter.
Figure 33. Example of Operator Status Displays
BULK
CHARGER STATE
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LEFT HAND
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
BUILD YEAR
POST - 2016
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
DISPLAY AND MENU OPTIONS
56
| www.hysecurity.com