Table 9. Viewing Operator Status Displays
Display
Variables
Description
Build Year
Indicates whether the gate operator
was manufactured before (pre-2016)
or after UL 325 - 2016 Standard
of Safety changes that require
monitoring of external entrapment
sensors.
All gate operators manufactured
in 2016 or later will show Build
Year - Post 2016 because it
contains software version h5.50
or later. If you plan to upload 5.50
software (or later) into your gate
operator, you will need to set the
appropriate build year according
to the date of manufacture.
Software Version
A lower case “h”
appears in front of
the software version
number.
Software version and revision number
are hard-coded in Smart DC Controller.
Displays software version when you
press RESET or cycle power. You will
need software version when calling
Technical Support.
Dual Gate or
Sequenced Gate
PRIMARY or SECONDARY
(Display only appears when operator
is used in bi-parting gate systems.)
Indicates, in a dual gate setting,
whether operator is set to Primary
or Secondary. Setting is assigned in
Installer Menu.
Operator Type (OT)
OT 12 = SwingSmart DC or DCS
Indicates and identifies the operator.
Set Handing (SH)
LEFT or RIGHT
Designates which way a gate opens
viewed from operator. If it slides
left, it is a left-hand gate. Gate
handing is established in the initial
Setup Menu.
Usage Class (UC)
1, 2, 3, or 4
Displays operator’s Usage Class
designation per UL 325 standards.
Bulk Charger State
Three stages of charging:
z
Bulk
z
Absorption
z
Float
Indicates the state of charging
that the AGM battery is currently
handling.
Input Voltage VDC
The number varies depending on
the voltage that the power board is
providing.
Input voltage (DC Buss voltage)
to the Smart DC is shown. Helps
to determine proper power
connections.
BT <0>
STANDARD BATTERY
0 = 8Ah (standard factory issue)
1 = 50Ah (optional upgrade)
2 = 110Ah (option)
Confirms operator’s battery type. If
you use larger capacity batteries you
must configure operator through
Installer Menu. See BT - BATTERY
TYPE.
DISPLAY AND MENU OPTIONS
57
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018