Table 11. Smart DC Controller - User Menu Functions
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
Associated
DC Controller
Connections
PE 0 (OFF)
Photo Eye Alignment
0 = off
1 = on
When set to 1, operator serves as an aide
in photo-eye emitter/receiver alignment.
Buzzer chirps once when emitter and
receiver are not aligned. When emitter
and receiver are aligned, buzzer chirps
twice. If they go out of alignment again,
buzzer will chirp once. Alignment Mode is
reset with a limit input or reset input.
Sensor
Common,
Sensor 1,
Sensor 2,
Sensor 3
CL 0
Set Clock
0 = Display
1 = Set Clock
To set or adjust minute, hour, day, month
or year, select 1. Once clock is set,
display automatically returns to 0 setting.
Significant gate events are logged and
stamped with time and date. This feature
is useful to read historical operation data,
which can be accessed with a computer
via USB or RS232 port or the LG setting
in User Menu. See "Setting the Time and
(N/A)
LD 5
LCD Contrast
5
0 through 9
Under some extreme high or low
temperature conditions, it may be
necessary to adjust LCD contrast. Display
is adjustable from 0-9 with a factory default
setting of 5.
(N/A)
LG 0
VIEW EVENT LOG
0 = off
1 = on
With v5.53 (or later) software, you can set
LG to 1 and view abbreviated event logs
on the display. These messages are helpful
for diagnostic purposes and reviewing the
gate operator’s event history. Over 300
events can be logged before the software
begins overwriting the existing history.
(N/A)
DS 0 (OFF)
DIAGNOSTIC LOGS
0 = off
(standard)
1 = on (detailed)
Set this item to 1 to record all gate
operator open and close events, in
addition to normal alert, fault and error
logs. This parameter automatically resets
to the default 0 (off ) after 24 hours, which
is useful when experiencing intermittent
problems. Set to 0, DC Controller logs
pertinent gate operator events such as
faults, errors, or menu manipulation.
USB or
RS232 cable
and laptop
computer with
HySecurity’s
free START
software is
required to
read log file.
DISPLAY AND MENU OPTIONS
65
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018