Table 12. Smart DC Controller - Installer Menu Functions
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
Associated
DC Controller
Display
Connections
OR 1 REVERSE
OUTSIDE OBS LOOP
0 = Pause closing
only
1 = Enable reverse
to open
Default is for full reversal when
Outside Obstruction Loop is triggered
while closing. A setting of 0 causes
gate to only pause when triggered.
Gate closure ontinues as soon as loop
is clear again.
OUTSIDE OBS
LOOP COM or
HY-5B
IR 1 REVERSE
INSIDE OBS LOOP
0 = Pause closing
only
1 = Enable
reversing to open
Default is for full reversal when Inside
Obstruction Loop is triggered while
closing. A setting of 0 causes gate to
only pause when triggered. Closure
begins as soon as loop is clear again.
INSIDE OBS
LOOP COM
or HY-5B
HD 1 HOLD OPEN
CENTER LOOP
HOLD
0 = Hold open only
1 = Hold close and
hold open
Configures the function of the Center
Loop (Shadow Loop) when triggered:
Setting 1 - prevents opening and closing
of the gate when the Center Loop is
tripped if the gate is on either (opened
or closed) limit switches.
Setting 0 - prevents closing when on the
open limit switch.
CENTER
LOOP
COM
DL 1 STANDARD
Detector Logic
1 = Standard
2 = Quick closed
3 = Forced Time out
4 = Full anti-tailgate
This selection determines whether
close timer begins to count down after
vehicles have departed detector loops
or whether close timer will count down
while the loops are occupied. Gate can
only close when all loop detectors are
clear.
Default settings causes Close Timer to
start when all loops are clear. A setting of
2 causes Close Timer to start when open
limit is reached. A setting of 3 forces
the Close Timer to 0 when the OOLD
and IOLD are tripped simultaneously. A
setting of 4 stops the gate when OOLD
and IOLD are tripped simultaneously
and closes from that point when the
loops clear.
HY-5B
DISPLAY AND MENU OPTIONS
74
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018