If required, adjust the sensitivity by accessing the
ELD, OOLD, IOLD, or CLD menu items in the
installer menu.
z
A = Automatic,
z
M = Motorcycle
z
0 = Low with boost (See NOTE.)
z
1 = Normal with boost (See NOTE.)
z
2 = High with boost (See NOTE.)
z
3 = X-High with boost (See NOTE.)
z
4 = Low without boost
z
5 = Normal without boost
z
6 = High without boost
z
7 = X-High without boost
10.
Vehicle detector functions are configurable
through the Installer Menu as described in
.
11.
Set the vehicle detector logic (DL).
NOTICE
A boost feature is applied for settings 0 through
3. Boost increases the sensitivity during a call
and is useful for maintaining continuous
detection if the signal becomes weak (such as
with tractor-trailer trucks). Sensitivity settings
4 through 7 are the same as 0 through 3, but
without the boost feature.
VEHICLE DETECTOR
Table 14. Vehicle Detector - Configurable Functions
Display
Meaning
Installer Menu Setting Options
(Bold - Default)
OR 1
Outside Obstruction loop detector
function
0 = Pause closing only
1 = Enable reverse to full open.
IR 1
Inside Obstruction loop detector function
0 = Pause closing only
1 = Enable reverse to full open.
DL 1
Vehicle detector logic
1 = Standard
(Close Timer does not begin
counting until all loops have cleared)
2 = Quick close (Close Timer can count to zero,
even while loops are active, so the gate will close
as soon as the loops are clear)
3 = Forced time out (Close Timer is forced to
zero when both the OOLD & IOLD are tripped
simultaneously. Additionally, all other close inputs
are memorized and the gate closes immediately
when all open commands and vehicle detector
inputs are clear.
4 = Full Anti-tailgate (In addition to the functions
of 3, the gate stops during the opening cycle when
both OOLD & IOLD are tripped simultaneously.).
When the OOLD and IOLD loops are cleared, the
gate closes immediately.
92
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018