Table 15. User-Programmable User Relays - Function Options
No.
Name
Description
23
External Latching Gate
Lock Output
Not functional in SwingSmart DC operators.
24
Gate at Partial Open
Position
Not functional in SwingSmart DC operators.
25
DC Power Alert
Active when on AC power or the battery voltage is above 21V. When
used with User Relay 2, this option can shed electrical loads to conserve
battery energy.
26
Free Exit Loop
Detector pulse
Outputs a 250ms pulse when the free exit vehicle detector is tripped.
27
Not Open (w/ AC
power)
Activated when gate is not on open limit and AC power is present.
Deactivated when AC power fails or gate is on open limit.
28
Flasher (w/ AC power)
Output identical to relay #19 and pulses relay 500 ms/sec when gate not
on open limit and AC power is present. Deactivated when AC power
fails or gate is on open limit.
29
Arm Entry Ticket
Dispenser
Not functional in SwingSmart DCt operator.
30
Arm Exit Ticket
Dispenser
Not functional in SwingSmart DC operator.
31
Resert Ticket Dispenser
Pulse
Not functional in SwingSmart DC operator.
32
Backoff Pulse
Not functional in SwingSmart DC operator.
33
Transient In Pulse
Not functional in SwingSmart DC operator.
34
Transient Out Pulse
Not functional in SwingSmart DC operator.
35
Tenant In Pulse
Not functional in SwingSmart DC operator.
36
Tenant Out Pulse
Not functional in SwingSmart DC operator.
37
Special In Pulse
Not functional in SwingSmart DC operator.
38
Special Out Pulse
Not functional in SwingSmart DC operator.
39
Unknown In Pulse
Not functional in SwingSmart DC operator.
40
Unknown Out Pulse
Not functional in SwingSmart DC operator.
41
Test Open Pulse
Output pulses five seconds after close limit is activated. Typically used
for cycle testing.
42
Break-Away Switch
Output
Activates when arm break-away switch is tripped.
43
Warn Before
Combination of relays #5 and #16.
44
Partial Open Limit
Pulse
Pulses for 250ms when gate, commanded with Partial Open input,
reaches Partial Open Limit, or, gate is past Partial Open Limit and Partial
Open input is activated.
45
Outside Obstruction/
Arming Loop Detector
Activated when OOLD/OALD detector input tripped and gate closed.
Used for testing purposes.
VEHICLE DETECTOR
96
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018