SAFETY INFORMATION
EMERGENCY STOP BUTTON
An emergency stop button that is accessible from
the outside of the operator is a requirement for
compliance with UL325 Safety Standards. The
red emergency stop button on the SwingSmart
operator is located inside a hole cutout on the
cover.
Pressing the emergency stop button while the
gate is opening or closing disables the automatic
close timer and stops gate travel. The gate travel
remains stopped until the operator receives any
open or close signal.
Make sure all users of the gate know where the
emergency stop button is located.
A screwdriver or hex key can be used to press
lightly on the switch to activate it.
Figure 1. Emergency Stop Button
EMERGENCY RELEASE
Make sure to teach all users how to turn off
electric power and how to move the gate
manually. SwingSmart allows a gate to be pushed
manually when the taper clamp is loosened. It is
recommended that you turn off DC power which
disengages the motor allowing you to easily move
the gate.
When you turn DC power off, the following occurs:
z
The motor disengages which keeps it from
running should any relay or open/close leaf
functions be set.
z
The GATE NO LOAD (FAULT 4) may appear on
the display.
To manually open the gate(s), take the following
steps:
1.
Remove the covers and turn off.
2.
Extend the taper handle and loosen the clamp
by turning the handle counter-clockwise. Refer
to Figure XXX.
3.
Swing the gate(s) open or close.
To return SwingSmart to automatic operation, take
the following steps:
1.
Make sure the gate(s) is not moving.
2.
Tighten the taper clamp until no slippage
occurs when you simulate a gate strike. Refer
"Setting the Taper Clamp" on page 37
3.
Flip the DC power switch ON.
4.
Clear any faults by pressing STOP or RESET.
23
| www.hysecurity.com
SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL
MX3640-01 REV. D ©2018