P
HOTO
E
YE
A
LIGNMENT
Most photo eyes require careful optical alignment in order to aim the emitter beam to
THECENTEROFTHERECEIVERORREÛECTOR)NORDERTOAVOIDFALSETRIGGERINGITISIMPORTANT
TOCAREFULLYALIGNTHESYSTEMESPECIALLYWITHRETROREÛECTIVEPHOTOELECTRICSENSORS4O
that end, HySecurity has provided a unique feature that turns photo eye power ON and
causes a buzzer to chirp when the photo eye enters and exits alignment.
Align the photo eyes using this feature by taking the following steps:
1. Move the gate off (away from) the close limit.
2. Access the User Menu and select PE. (To access the User Menu, press the
Menu button twice. For a refresher on using the Menu Mode navigational
buttons, see the chart on page 9.)
3. Set the menu item PE 0 to PE 1.
4. Move the photo eyes (up/down, side to side) to align the emitter beam. The
buzzer will chirp once when the beam is broken and twice when remade.
5. When the buzzer chirps once, indicating the photo eyes are aligned, set the
next photo eye (if the site has one) and continue the process until all photo
eyes are aligned.
6. Close the gate. When the close limit is triggered, the User Menu item PE
resets to 0.
NOTE:
-OUNTPHOTOEYESAPPROXIMATELYTOINCHES TOCMABOVETHEGROUNDANDASCLOSETOTHEGATEASPOSSIBLE
PREFERRABLYWITHININCHES CM&ORMOREINFORMATIONREFERTO
ASTM F2200 Gate and Fence Standards
and your gate operator
product manual.
T
ROUBLESHOOTING
The Smart Touch Controller reports system malfunctions using three simultaneously occurring methods:
• Codes presented on its display (alert, fault or error)
•
!CTIVATIONOFABUZZERWHICHEMITSASERIESOFCHIRPSATDEÚNEDINTERVALS
• Stop gate travel (and/or reverse direction of travel)
Overriding a tripped sensor or fault condition on a HySecurity gate operator with monitored
entrapment sensors requires a 2-step process:
• Press Open or Close momentarily. Audible beeps in quick succession indicate tripped
sensors or fault conditions.
• Within 5 seconds of hearing the beeps, apply constant hold pressure to override
the tripped sensor or fault. The gate operator runs while pressure is maintained to
actuating device (examples include, Push button Open, Push button Close, Open
Partial or Keypad Open/Close), or a limit is reached, or another sensor trips.
To help in diagnosing a controller board problem, the active status of each input on the Controller is indicated by its
associated LED.
• On AC- powered gate Operators: Active-input LEDs are always illuminated.
• On DC- powered gate Operators (with AC input OFF or disconnected): Press and hold the Tact button to
illuminate the active-input LEDs.
A short list of codes appears on the next page and provides additional troubleshooting solutions. For a complete list of
troubleshooting codes, refer to the Troubleshooting Codes table in your gate operator’s
Programming and Operations
manual.
FAULT 2
SENSOR #1
HYSECURITY
GATE STOPPED
PE 1 (ON)
PHOTO EYE ALIGN
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
PE 1 (ON)
PHOTO EYE ALIGN
www.hysecurity.com
©
2016
Quick Start
D0726 Rev. C
23
Summary of Contents for UL 325-2016
Page 33: ...Page intentionally left blank...