Since HySecurity gate operators use software to control gate movement, contacts, and accessories, the changeover to
monitored sensors is simple. In fact, the ability to monitor sensors has always been an available Installer Menu item. (Refer
TO4ABLE3ETTINGTHE3ENSOR,OGICONPAGE )NSTEADOFANOPTIONITNOWBECOMESTHEDEFAULTSTANDARD
• Build Year is a new Installer Menu item in Smart DC and Smart Touch Controllers versions h5.50 and h4.50 (and
higher).
•
.EWLABELSSHOWWHERE%DGE0HOTO%YE/PENAND0HOTO%YE#LOSEDHAVECHANGEDTO3%.3/2INPUTS9OU
can program the type of sensor wired to one of those inputs. See illustrations on page 6 and Table 4 below.
• Installer Menu items, PC and GC (Photo eye output and edge sensor output) which used to default to Normally
Open (NO) have been converted to Normally Closed (NC) contacts so the software can detect the presence and
proper operation of entrapment protection sensors.
Table 4: Changes to Sensor Inputs on the Controller
Location of Sensor Inputs on Controller
Installer Menu Item Codes
Smart Touch Controller (STC): Hydraulic gate operators
Smart Touch Display:
Input #
Current Silk Screen Label
2016 Silk Screen
Label
OLED - two line,
32 character
LCD - 7
segment text
13
EDGE SENSOR
SENSOR 1
S1 SENSOR 1
6
17
PHOTO EYE OPEN DIRECTION
SENSOR 2
S2 SENSOR 2
6
19
PHOTO EYE CLOSE DIRECTION SENSOR 3
S3 SENSOR 3
6
Smart DC Controller (SDC):
Electromechanical gate operators
Smart DC Display:
32 character LCD
No numerical input
number appears on
Smart DC
EYE OPEN
SENSOR 2
S2 SENSOR 2
EYE CLOSE
SENSOR 3
S3 SENSOR 3
EDGE
SENSOR 1
S1 SENSOR 1
NOTE:
4HREEINPUTSFOREXTERNALENTRAPMENTPROTECTIONSENSORSAREAVAILABLEONTHE(Y3ECURITYGATEOPERATORCONTROLLER.EWSILK
screen controller boards are on order, but until they are ready for shipment, labels will be overlaid on the board to indicate
terminology adaptations.
4ABLEINDICATESHOWTHEEDGEANDPHOTOEYEINPUTSHAVEBEENRENAMEDTOGENERICSENSORINPUTS4HEYARE
INTERCHANGEABLEANDCONÚGURABLE4HESOFTWAREMUSTKNOWWHATTYPEOFSENSORISWIREDTO3%.3/2AND
BEFORE
it
will allow gate travel. Refer to page 9.