MAINTENANCE
103
b. Open the liquid outlet valve and by--pass return
valve on the storage tank.
c. Start the pump.
d. Connect the supply hose to the quick disconnect
fitting on the LPG tank. If the LPG tank has an aux-
iliary fill fitting, connect the supply hose to this fit-
ting. Make sure the correct adapter is used to con-
nect the supply hose to the auxiliary fill fitting.
e. Open the vent valve on the liquid level indicator.
f. Open the fuel valve on the LPG tank.
g. Open the valve on the end of the supply hose.
h. Watch for a discharge from the vent valve on the
liquid level indicator. When a cloud of visible vapor
appears, the LPG tank is full. Do not fill the LPG
tank more than the maximum level indicated by the
liquid level indicator. Immediately close the valve at
the end of the supply hose.
i. Close the vent valve on the LPG tank.
j. Close the fuel valve on the LPG tank.
k. Disconnect the supply hose.
l. Stop the pump.
m. Close the liquid outlet valve and the by--pass return
valve on the storage tank.
Gasoline or Diesel Fuel
1. Remove the fuel cap. Make sure the fuel tank is filled
with the correct fuel for the type of engine in the lift truck.
Clean the fuel cap.
2. Replace the fuel cap.
WARNING
When fuel is added, keep the funnel or fuel nozzle in
contact with the metal of the fuel tank to reduce the
possibility of static electric sparks. Clean any spilled
fuel.
Property of American Airlines