Inspection
6
─
93
─
Drain plug
Oil level plig
1. Inspection of differential gear oil
Remove the level gauge plug and confirm
the oil level. The oil level should be at
level gauge hole. If the level is lower, then
replenish. If the oil is dirty, change the oil.
2. Inspection of torque converter oil
Remove the floor plate and pull out the
dipstick. The oil should be between holes
(
“F”
and
“L”
) on the dipstick. Replenish
the oil if insufficient and replace if dirty.
Replace the oil for the first time after
six months of use, and after that
replace it every 12 months.
ADVICE
Dipstick for transmission
Do not permit dirt to enter the
transmission when the oil level is
checked.
CAUTION
● When inspecting the oil level, rotate the engine, and then stop and
inspect within one minute.
● Replace the torque converter return filter element for the first time after
six months of use, and after that replace it every 12 months. The torque
converter suction strainer must be cleaned every six months. This
strainer does not need to be replaced.
● Replace the oil every 6 months.
ADVICE