Normal Sequence of Operation - Display
Panel With Options
Following is the normal sequence that occurs after the
operator is on the seat with the battery connected:
NOTE:
If the password or operator check features are not
enabled, the
Operator Screen
will appear after the key or
keyless switch is moved to the
ON
position.
•
After the key or keyless switch is moved to the
ON
posi-
tion, the
Password Screen
will be on the LCD screen if
this function is enabled.
•
After password is correctly entered, or if it is disabled,
the first item of the Operator Checklist will be on the LCD
screen if this function is enabled.
•
After Checklist is complete, or if it is disabled, the LCD
screen will display the
Operator Screen
and the icons
will appear on the LCD
screen. After 10 seconds, the seat belt, low brake fluid,
service due (if enabled), motor temperature icons, and
low hydraulic fluid (if enabled) will no longer be illumina-
ted and will illuminate again only if there is a problem in
those areas.
•
The last Performance Mode operation will be on the LCD
screen as MODE #___. The bar graph for battery-state-
of charge is also on LCD screen. If the battery is dis-
charged to lift-interrupt, the battery indicator symbol will
also be flashing. If a battery of the wrong voltage has
been installed, the Wrench symbol will also be flashing.
Correct these problems before attempting normal opera-
tion.
Turn the key or keyless switch to the
OFF
position. The fol-
lowing display sequence will occur:
•
Display panel shows the hourmeter hours for the truck
and hydraulic pump motors. See
Display Panel Features
77