User Manual
Debugging
37
6. Debugging
Use the Product Support Software (PSS) to configure and upgrade the DS-9300 device.
6.1
Preparation
Before debugging, prepare the PSS tool, and connect the device to the computer. You can debug the
device either locally through the cable or IP connection, or remotely through IP connection. The default IP
address of the device is 192.168.1.100; the IP address of the computer must be set to the same network
segment, 192.168.1. X (X cannot be 100).
The computer for running the PSS must meet requirements specified in the following table:
Item
Description
Operating system
Windows7 or above
CPU
PII300 or above
Memory
128 MB or above
Storage
2 GB or above
Display
14-inch or above, resolution 800x600 or above
6.2
Procedure
The process of local debugging and remote debugging is the same. In this document, local debugging is
taken as example. For remote debugging, please refer to
Repeater Management System Operation Guide
.
1. Double-click "DS9300_PSS.exe" on the computer. The following main interface appears.
Summary of Contents for DS-9300