background image

 

Ending an Individual Call 

Press 

  to end the call.   

5.2 

Group Call 

A group call is a half-duplex call initiated by an individual user to other members in a predetermined 

group. You can initiate a group call to the default group, and receive group calls from the members of the 

group.   

Initiating a Group Call 

On the home screen, rotate the 

Group Selector

 knob to select a group and hold down the 

PTT

 key to 

initiate a group call to this group, whose number is displayed on the home screen.   

Answering a Group Call   

You can answer a group call without any operation.   

Ending/Exiting a Group Call 

  The calling party can press 

  to end the group call.   

  The called party can press 

  to exit the group call.   

5.3 

PABX/PSTN Call 

A PABX/PSTN call is a full-duplex individual call with Hook Signaling established between an individual 

user and a PABX or PSTN user outside the TETRA network.   

The operations for initiating a PABX/PSTN call are as follows. For operations of answering or ending a 

PABX/PSTN call, refer t

5.1Individual Call

. 

Initiating a PABX/PSTN Call   

Step 1 

On the home screen, press the 

Func/OK

 

key to go to “Settings -> Network” and select “PSTN 

GW” or “PABX GW”.   

Step 2 

Return to the home screen and input a PABX or PSTN number. 

 

Step 3 

Press the 

Func/OK

 key to select 

“PABX” or “PSTN” if 

appears on the screen.   

Skip this step if 

does not appear on the screen.   

Step 4 

Press 

  to initiate the call.   

5.4 

Emergency Call 

An Emergency call is a call initiated by an individual user to the predefined contact for summoning help 

in urgent situations. With the highest priority, it can interrupt any other ongoing calls with lower priority if 

Summary of Contents for TETRA PT560H F4

Page 1: ...optimum performance from the product please read this manual the corresponding TETRA Terminal SeriesFeature Book and the Safety Information Booklet carefully before use This manual is applicable to t...

Page 2: ...e at http www hytera com FCC Regulations Federal Communication Commission FCC requires that all radio communication products should meet the requirements set forth in the above standards before they c...

Page 3: ...certified by the qualified laboratory the product is in compliance with the essential requirements and other relevant provisions of the Directive 1999 5 EC Please note that the above information is ap...

Page 4: ...12 3 5 Attaching the Accessories 12 3 6 Charging the Battery 13 4 Basic Operations 15 4 1 Turning On Off the Terminal 15 4 2 Switching Operation Mode 15 4 3 Adjusting the Call Volume 15 4 4 Selecting...

Page 5: ...10 FCC STATEMENT 25...

Page 6: ...eceived If any item is missing or damaged please contact your dealer Terminal Antenna Belt Clip Strap Charger Battery Power Adapter Documentation Kit Note The frequency band is marked on the label of...

Page 7: ...Part Name No Part Name 1 SK1 Side Key 1 15 Antenna Connector 2 PTT Push to Talk Key 16 Power On Off Volume Control Knob 3 SK2 Side Key 2 17 Half duplex Microphone 4 Emergency Key 18 Accessory Connecto...

Page 8: ...2Key andF3Key as shortcuts to certain features For the detailed introduction please refer to the corresponding TETRA Terminal Series Feature Book 2 2 LCD Icon Icon Terminal Status The terminal is not...

Page 9: ...GPS or GLONASS data is received The GPS feature is active but no valid GPS or GLONASS data is received A wireless accessory is connected and available for use The BT feature is enabled but no wireless...

Page 10: ...ter is in progress An AIE call via repeater is in progress The AIE and E2EE call via repeater is in progress An Emergency call is in progress A broadcast call is in progress 2 3 LED Indicator LED Indi...

Page 11: ...turn off the terminal first Then lift the battery latch and remove the battery 3 3 Installing the SIM Card If you have purchased the End to End Encryption E2EE feature which is realized via a SIM card...

Page 12: ...the two screws on the back of the terminal Step 2 Align the screw holes on the belt clip with those on the terminal and then tighten the screws as shown in the figure below 3 5 Attaching the Accessori...

Page 13: ...of the accessory 3 6 Charging the Battery Caution Use the charger specified by the Company to charge the battery Make sure the terminal is powered off before charging Read the Safety Information Bookl...

Page 14: ...ging status indication on charger LED Indication Charging Status Flashes red slowly Standby no load Glows red Charging Glows orange 90 charged Glows green Fully charged Flashes red rapidly Charging fa...

Page 15: ...n the home screen to enter the Mode menu and then select TMO or DMO to switch the operation mode 4 3 Adjusting the Call Volume 4 4 Selecting a Group 4 5 Managing the PhoneBook PhoneBook is used to sav...

Page 16: ...key and go to PhoneBook menu to select an individual contact Step 2 Press to initiate a full duplex individual call Step 3 Both parties can talk at any time without any operation after the call is est...

Page 17: ...l A PABX PSTN call is a full duplex individual call with Hook Signaling established between an individual user and a PABX or PSTN user outside the TETRA network The operations for initiating a PABX PS...

Page 18: ...vice Message Service allows you to send and receive a message which includes Status Message and User Message Status Message is programmed by your dealer only while User Message allows you to create ed...

Page 19: ...ished Answering an Individual Call You can answer the call without any operation Ending an Individual Call Press to end the call 6 2 Group Call The group call operations in DMO are similar to those in...

Page 20: ...6 4 Message Service The message operations in DMO are similar to those in TMO Refer to 5 5Message Service for details...

Page 21: ...verage The terminal may operate in an improper mode Check the operation mode Make sure the terminal works in the right mode A certain group call cannot be initiated or received The terminal may not be...

Page 22: ...te at an unfavorable position where communication may be blocked by high buildings or frustrated in the underground areas in DMO Move to an open and flat area and restart the terminal As for the same...

Page 23: ...when the product is not in use Product Cleaning Caution Power off the product and disconnect the power supply before cleaning Clean up the dust and fine particles on the product surface and charging p...

Page 24: ...dealer or us for more details on the main optional accessories of the product Caution Use the accessories specified by the Company only If not the Company shall not be liable for any losses or damage...

Page 25: ...with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause h...

Page 26: ...si le brouillageest susceptible d en compromettre le fonctionnement The information listed above provides the user with information needed to make him or her aware of a RFexposure and what to do to as...

Reviews: