Before operating the log splitter, the Bleed Screw should be loosened by some
rotations until air can go in and out of the oil tank smoothly.
Air flow thru the Bleed Screw hole should be detectable during the log splitter is
under operations.
Before moving the log splitter, make sure the Bleed Screw is tightened to avoid oil
leaking from this point.
FAILED TO LOOSEN THE BLEED SCREW WILL KEEP THE SEALED AIR IN HYDRAULIC
SYSTEM BEING COMPRESSED AFTER BEING DECOMPRESSED. SUCH CONTINUOUS
AIR COMPRESSION AND DECOMPRESSION WILL BLOW OUT THE SEALS OF THE
HYDRAULIC SYSTEM AND CAUSE PERMANT DAMAGE TO THE LOG SPLITTER.
15. Max Pressure Limiting Screw
DO NOT ADJUST THE MAX PRESSURE
LIMITING SCREW !
Max pressure was set before the log
splitter ex work and the max pressure
limiting screw is sealed with glue to
ensure the log splitter works under
pressure no more than 5 tons. The
setting was done by qualified
mechanic
with
professional
instruments.
Unauthorized resetting will cause the
hydraulic pump fail to output enough
splitting pressure or
RESULT IN SERIOUS
INJURY AS WELL AS DAMAGE TO THE
MACHINE .