7-24
S.R.O.
If this option is set to on the static return to off is requested for starting the truck. The required
sequence is :
Â
Seat-direction lever-accelerator pedal or :
Â
Seat-accelerator pedal-direction lever within the seq. delay time
If this option is set to off the required sequence to start the truck is :
Â
Direction lever-accelerator pedal or :
Â
Accelerator pedal-direction lever within the seq. delay time
P
P
edal type
- OPTION #1 : The pedal position is sent to the display for graphic indication.
- OPTION #2 : The speed set-point is sent to the display for graphic indication.
Pedal brake stop
If set to on the truck is stopped when the pedal brake is pressed.
If set to off the traction current is reduced to the half of the maximum current.
Submenu "ADJUSTMENTS"
Set pot brake min
It records the minimum value of braking pedal potentiometer when the braking pedal switch is
closed; the procedure is similar to the "Program Vacc" function (see page 7-37). This procedure
must be carried out only if the "Pedal braking" option is programmed as "Analog".
Set pot brake max
It records the maximum value of braking pedal potentiometer when the braking pedal is fully
pressed; the procedure is similar to the "Program Vacc" function (see page 7-37). This procedure
must be carried out only if the "Pedal braking" option is programmed as "Analog".
Set battery type
It selects the nominal battery voltage.
Adjust battery
Fine adjustment of the battery voltage measured by the controller.
Ρ
Σ
Η
Θ
Ι
Κ
(
(
2)