7-62
CHARGER INSTALLATION METHOD
Location for charger installation
Dry and well ventilated place.
No inflammable and B7 fire are near by.
Safe place where no collision possibility
with people or equipment is.
Check points before installing charger
Enough capacity of AC input power
source to operate charger.
Standard electric wire for power source
by capacity.
HOW TO USE A CHARGER
General charging method (Floating
charging)
Charging by this method supplies electric
power to the charger as operating
external AC power switch of the charger.
Connect battery connecter and charger
connecter.
Â
Â
According to charging condition
If there is no abnormality found when the
charger checks itself for 3-4 seconds
after inputting AC input power source, the
charger slowly increases the electric flow
for charging and the charging condition
lamp in the lower part of the front panel
for floating charging of "input" is on.
When charging is processed about 80%,
yellow lamp in the middle of the front
panel, which shows that the charging
condition is in the middle, is on and then
green lamp is on when charging is
processed over 85% until charging is
completed.
When charging is completed, "charging is
completed" lamp is on in the monitor and
other lamps of all monitors become off.
(1)
Η
Θ
Ι
Η
Θ
(
(
2)
Η
Θ
BR7BAT10
Display
Η
Ι
Η
Θ
Θ
2
2
)
3)
Η
Θ
Ι
(
(
1)