background image

Safety

 

labels

 

information

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

TRANSPORT

 

WARNING

 

 

!

 

Never

 

lift

 

the

 

generating

 

set

 

by

 

attaching

 

to

 

the

 

engine

 

or

 

alternator

 

lifting

 

lugs,

 

instead

 

use

 

the

 

lifting

 

points

 

on

 

the

 

base

 

frame

 

or

 

canopy.

 

!

 

Ensure

 

that

 

the

 

lifting

 

rigging

 

and

 

supporting

 

structure

 

is

 

in

 

good

 

condition

 

and

 

has

 

a

 

capacity

 

suitable

 

for

 

the

 

load.

 

!

 

Keep

 

all

 

personnel

 

away

 

from

 

the

 

generating

 

set

 

when

 

it

 

is

 

suspended.

 

 
 

 

MECHANICAL

 

WARNING

 

 

!

 

Do

 

not

 

attempt

 

to

 

operate

 

the

 

generating

 

set

 

with

 

the

 

safety

 

guards

 

removed.

 

While

 

the

 

generating

 

set

 

is

 

running

 

do

 

not

 

attempt

 

to

 

reach

 

under

 

or

 

around

 

the

 

guards

 

to

 

do

 

maintenance

 

or

 

for

 

any

 

other

 

reason.

 

!

 

Keep

 

hands,

 

arms,

 

long

 

hair,

 

loose

 

clothing

 

and

 

jewelers

 

away

 

from

 

pulleys,

 

belts

 

and

 

other

 

moving

 

parts.

 

 

 

SAFEGUARD

 

WARNING

 

 

!

 

Generating

 

sets

 

that

 

are

 

not

 

equipped

 

with

 

sound

 

attenuating

 

enclosures

 

can

 

produce

 

noise

 

levels

 

in

 

excess

 

of

 

105

 

dB

 

(A).

 

Prolonged

 

exposure

 

to

 

noise

 

levels

 

above

 

85

 

dB

 

(A)

 

is

 

hazardous

 

to

 

hearing.

 

!

 

Wear

 

protective

 

clothing

 

including

 

gloves

 

and

 

hat

 

when

 

working

 

around

 

the

 

generating

 

set.

 

 

 
 
 
 
 
 

!

 

If

 

equipped

 

keep

 

access

 

doors

 

on

 

enclosures

 

closed

 

and

 

locked

 

when

 

not

 

required

 

to

 

be

 

open.

 

!

 

Avoid

 

contact

 

with

 

hot

 

oil,

 

hot

 

coolant,

 

hot

 

exhaust

 

gases,

 

hot

 

surfaces

 

and

 

sharp

 

edges

 

and

 

corners.

 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for DHY11KSE

Page 1: ...Diesel Generator User Manual...

Page 2: ......

Page 3: ...s close to the battery and fuel because the mixture of volatilization from fuel and hydrogen generated by battery charging process will cause explosion when it meets sparkle or naked flame The generat...

Page 4: ...is running do not attempt to reach under or around the guards to do maintenance or for any other reason Keep hands arms long hair loose clothing and jewelers away from pulleys belts and other moving...

Page 5: ...al disconnected prior to attempting to connect or disconnect load connections Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Make sure conne...

Page 6: ...rator Set Working Room 4 2 5 Installation of Generator Set 5 2 6 Cooling system 7 2 7 Lubricant system 8 2 8 Fuel system 8 2 9 Battery 10 2 10 Electrical Connection 11 2 11 Power distribution system 1...

Page 7: ...andby power supply to provide continue electric power for non invariable loads The generator set is suitable for the area where must ensure continue power supply such as hospitals industrial facilitie...

Page 8: ...pusher fan and thermostat The alternator has its own internal fan to cool the alternator components 1 6 Electrical System The engine electrical system is 12 volt or 24 volts DC negative ground earth...

Page 9: ...litated onnect direc valve is an UNDAI Pow n for the rplus lubrica t by openin ransportatio been designe Standard ca fting hole o enerator set canopy roo me which b o have stati the generato Optional...

Page 10: ...ect to other architecture s foundation The width and depth of foundation shall meet requirement Ensure foundation s levelness and smoothness If possible waste discharge sink can be sued so that the wa...

Page 11: ...et to outside For example corrugated vibration reduction pipe has been used to connect exhaust pipes air exhaust path fuel inlet pipe fuel return pipe and busbar cable etc all of these parts need to u...

Page 12: ...ssure and side stress Reserve some space for hot shrinkage and cold expansion Reserve space for generator set vibration Reduce exhaust noise level Overload of exhaust backpressure will cause following...

Page 13: ...the liquids in a separate container evenly and then add the mixture into the radiator ensure the anti freeze will not freeze under low temperature In the area when there is low possibility of freezing...

Page 14: ...specification as that existing in the radiator For some generator sets installed with coolant filter please open the filter s valve before put into use 2 7 Lubricant system Lubricant system is compose...

Page 15: ...or sets provide base frame style fuel tank for customer The base frame style fuel tank is installed with fuel tank fuel pipes and fuel level indicator This fuel supply system does not need customer to...

Page 16: ...are required to correctly connect the signal line to this control panel details see the control panel operation manual Automatic transfer panel optional is the automatic transfer switch for transfer...

Page 17: ...t be connected to an earth ground Since the set is mounted on vibration isolators the ground connection must be flexible to avoid possible breakage due to vibration Ground connection cables or straps...

Page 18: ...tart Part of the generator set control panel has been furnished with idle speed full speed transfer switch users can choose if the engine need to be started in idle speed or in one time full speed Usu...

Page 19: ...ing situation and if there is any malfunction warning generator set shut down etc Only when the correct and complete record for running maintenance has been kept very well the user can get correct and...

Page 20: ...number 3 times the Alarm LCD would flash If you need to restart wait at least 30 seconds before the retry 8 Check the reading of Voltage Meter and Frequency Meter by operating the Voltmeter Change Ov...

Page 21: ...ight means AMF controller is active then user can select operation type OFF MAN AUTO MEASUREMENT A OFF mode Start stop mains power on off generator set power on off is inactive in this mode B MAN mode...

Page 22: ...if generator set is used for self start standby power In order to achieve full automatic transfer between mains power and generator set power to guarantee all load present our ATS panel select the bes...

Page 23: ...O that is OK detail operate step refer module control system ATS PANEL introduction No MODEL 1 ATS switch 2 panel lock 3 mains power output hole 4 generator power output hole 5 communicate with genera...

Page 24: ...battery For each 50 600 hours of running or at least each 12 months Change lubricant and lubricant filter Because the quality of lubricant oil sulfur content of the fuel and lubricant consumption rate...

Page 25: ...refer to Control Panel Operation Manual for details 4 5 Start battery Batteries which have been stored in a long time shall be properly charged before being used so that to ensure normal capacitance o...

Page 26: ...iminate the malfunction s Especially important for new generator set s customer One thing must to be emphasized most of the malfunctions are caused by user s improper installation operation and mainte...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Page 35: ...DHY10KE KSE DHY250KE KSE...

Page 36: ...DHY10KE KSE DHY250KE KSE...

Page 37: ...DHY10KE KSE DHY250KE KSE...

Page 38: ...DHY10KE KSE DHY250KE KSE...

Page 39: ...DHY10KE KSE DHY250KE KSE...

Page 40: ...DHY10KE KSE DHY250KE KSE...

Page 41: ...APPENDIX E 1...

Page 42: ...2...

Page 43: ...3...

Page 44: ...running record TIME ENGINE PARAMETER GENERATOR PARAMETER IF RECORD FOR MALFUNCTION IS AVAILABLE OPERATOR REMARK Start stop generator set time Accumulated running time Oil pressure Temperature Voltage...

Page 45: ...serial No Engine serial No Alternator serial No Accumulated running hours Maintenance cycle Reasons for maintenance periodic maintenance or malfunction maintenance Inspection and repair Inspection an...

Page 46: ...APPENDIX H...

Page 47: ......

Page 48: ...Licensed by Hyundai Corporation Korea For Inquiries Please Contact GRV POWER PRODUCTS S L Avda Alguema 8A 17771 Sta LLogaia Alguema Spain Tf 34 972 67 38 36 www hyundaipower es...

Reviews: