5.
TROUBLESHOOTING
MACHINE WILL NOT START
CAUSE
REMEDY
Check the control system
power
Poor connections
Check all connections including
all plugs and sockets
Low battery
Charge/replace the battery
Check fuel and oil
No Fuel
Fill with diesel fuel
No Oil
Fill with oil
Poor quality fuel
Replace old/stale fuel
Check cylinder compression
Piston ring worn or rings in
wrong place
Contact your dealer
Valve clearance is in-correct
Bolts of cylinder head are
not tighten
Check fuel supply system
Blocked fuel pipes
Clear blockages or replace as
required
NO OUTPUT VOLATGE
CAUSE
REMEDY
Check circuit breaker
Circuit breaker not switched
ON
Turn circuit breaker to ON
position
Circuit breaker is faulty
Replace the breaker
Check AVR
AVR is broken
If no output after all other
checks
Possible alternator failure
Contact your dealer