User manual
12
3
Operation
3.1
Inspect
Before
Operation
After
finished
installation,
our
diesel
engine
generator
set
can
be
put
into
use.
Each
time
before
starting
the
generator
set,
following
items
shall
be
checked
without
fail:
◆
If
there
is
foreign
material
exists
in
the
surface
of
generator
set
or
in
the
ambient
environment
which
may
hamper
the
generator
set’s
operation.
◆
If
the
air
inlet
and
ventilation
path
in
the
generator
set
working
room
is
expedite.
◆
If
the
anti
‐
freeze
level
is
normal.
◆
If
the
air
filter
indicator
works
well
◆
If
the
lubricant
level
is
within
the
specified
range
◆
If
the
fuel
valve
is
open,
if
the
fuel
has
been
supplied
to
the
engine
normally.
◆
If
the
cable
has
been
connected
to
the
battery
in
a
correct
way.
◆
Check
if
the
load
equipment
has
been
well
prepared.
When
the
generator
set
directly
connects
to
the
load,
the
air
switch
shall
be
cut
off
before
start.
Warning:
Operators
shall
establish
good
operation
(maintenance)
procedure,
this
is
the
precondition
for
generator
set’s
smooth
running
in
long
time
period.
3.2
Generator
set’s
running
3.2.1
Pre
‐
heat
For
the
generator
set
which
is
installed
with
pre
‐
heater,
operators
need
to
decide
if
pre
‐
heating
is
needed
before
start
the
generator
set
according
to
environment
temperature.
The
control
panel
which
is
installed
with
pre
‐
heat
switch
can
instruct
the
engine
to
start
the
pre
‐
heater
so
that
to
achieve
the
purpose
of
pre
‐
heating.
3.2.2
Connect
to
power
Turn
the
air
switch
in
the
control
panel
from
“OFF”
to
“ON”,
watch
the
panel
until
the
background
light
turn
on,
that
means
the
control
panel
has
been
successfully
connected
to
the
power.
At
the
same
time
make
sure
the
fuel
pipes
are
open,
and
the
speed
governor
or
the
control
unit
in
the
electronic
fuel
injection
generator
set
is
under
working
status.
3.2.3
Start
Part
of
the
generator
set
control
panel
has
been
furnished
with
idle
speed
/
full
speed
transfer
switch,
users
can
choose
if
the
engine
need
to
be
started
in
idle
speed
or
in
one
time
full
speed.
Usually
the
time
period
for
idle
speed
shall
not
exceed
five
minutes.
Do
not
run
the
generator
set
in
idle
speed
in
a
long
time
period.
Press
on
the
start
button,
the
duration
shall
not
exceed
30
seconds,
engine
will
be
started
by
the
start
motor.
As
soon
as
the
engine
be
started
successfully,
you
can
release
the
start
button
and
the
generator
set
will
enter
into
running
status.
Suggestion:
In
order
to
extend
the
life
expectancy
of
start
battery
and
start
motor,
the
duration
for
one
time
start
shall
be
controlled
within
5
to
10
seconds.
If
one
time
start
fails,
stop
for
some
time
and
begin
the
second
time
start
procedure.
For
the
control
panels
which
are
installed
with
self
‐
start(or
communication)
instrument,
the
generator
set
pre
‐
heating,
start
‐
up
period
and
starting
times
have
been
controlled
by
the
program
(this
program
can
be
set
and
modified
by
user).
Operation
procedure
please
refers
to
operation
manual.
When
the
generator
set
control
panel
has
malfunction(s),
timely
overhauling
is
needed
before
Re
‐
start
the
control
panel.
Warning:
For
any
start
up
which
is
made
through
force,
not
by
control
panel,
the
malfunction
caused
by
it
do
not
belong
to
the
scope
of
warranty.
3.2.4
Running
When
the
generator
set
begins
full
speed
running,
and
the
alternator’s
voltage
and
frequency
becomes
normal
and
stable,
operators
can
put
the
generator
set
into
normal
running.
During
the
generator
set’s
running
period,
operators
shall
often
watch
and
check
the
parameters
such
as
if
the
generator
set
is
running
normally,
if
the
control
panel
instrument
is
indicating
the
right
position,
if
the
control
panel
has
pre
‐
warning
indication,
and
the
fuel
level
in
the
base
frame
etc,
and
make
record
for
the
parameters.
(see
attach
file)
3.2.5
Emergency
stop
In
case
the
generator
set
was
found
to
have
severe
Summary of Contents for DHY34KSE
Page 2: ...DIESEL GENERATOR Models Hyundai Engine Series Operation and Maintenance manual ...
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ...APPENDIX E 1 ...
Page 40: ...2 ...
Page 41: ...3 ...
Page 44: ...APPENDIX H ...
Page 45: ......