10
3.4 Checking the Generator before start up.
1.
Turn
off
the main breaker switch and remove all loads.
Be sure to turn off the main breaker switch before starting. The generator should be
earthed to prevent electric shocks.
- Before starting the engine, be sure to switch OFF any appliances connected to it.
- Ensure that the breaker switch is OFF before switching between 115v/230v.
3.5 How to open the cabinet door and covers of this Hyundai generator
1.
Open the cabinet door for daily inspection. Turn the lever counter clockwise and
raise the door.
2.
Loosen the bolt of the air cleaner cover to check the air cleaner.
3.6 Break-in Period Operation
The first 20 hours are the break-in period of the engine. For this reason, it is important to
follow the following instructions during this period.
Warm up the engine 5 minutes after the initial starting, before applying load.
Avoid applying loads above 3kw during the first 20 hours of operation.
It is important to replace the engine oil on time. Replace the engine oil whilst the
engine is warm, after 20-hours running. Ensure that old engine oil is drained out
completely.