26
No DC output
1.
Disconnect battery, reset breaker and test the
battery for shorts.
2.
Clean battery connector nodes.
Generator
outputs
unstable
power
Connected
device does
not operate
consistently
Verify device start up requirements (Wattage
consumption). Do not exceed the generators
maximum peak output.
Device will not
start up
1.
Remove all loads, reset breaker, and check
device for defects. Do not exceed generator
rating.
2.
Ensure device’s wattage consumption does
not exceed the generator’s maximum peak
output.
Engine idle
unusually high
or low
Carburetor in need of tuning. For details on how to
adjust correctly please contact your local service
centre, or contact Midland Intl Inc. at 1-877-528-
3772.
Generator
overheats
Operation is
normal when
generator
is cool,
overheating
occurs within
moments of
start up.
1.
Atmospheric temperature high (excess of
35°C).
2.
Insufficient air circulation in vicinity of
generator.
3.
Low oil viscosity, use 10W40 when
temperatures exceed 30°C, 10W30 for
temperatures between 0° ~ 30°C, and 5W40
for temperatures below 0°C.
4.
Fouled spark plug, replace with equal or
greater quality plug.
Engine idle
fluctuates
1.
Carburetor in need of tuning. For details on
how to adjust correctly please contact your
local service centre, or contact Midland Intl
Inc. at 1-877-528-3772. Missing ground
reference on return side of differential analog
output (external).
2.
Air filter element obstructed by debris. Clean
according to user guide instructions on page
11.
Summary of Contents for GreenPower
Page 1: ...HYUNDAI PORTABLE INVERTER USER GUIDE ...
Page 36: ...36 ...
Page 38: ...38 ...
Page 39: ...39 Enjoy Be sure to check www hyundaipower ca for updates regarding your generator ...
Page 40: ......
Page 41: ...HYUNDAI ONDULEUR PORTATIF MANUEL D UTILISATION ...
Page 78: ...38 ...
Page 80: ......