ABSOLUTE MAXIMUM RATINGS
Note :
Operation at above absolute maximum rating can adversely affect device reliability
DC OPERATING CONDITION
(TA=0 to 70
°
C
)
Note :
1.All voltages are referenced to V
SS
= 0V
2.VDD(min) of HY57V641620HG(L)T-5/55/6 is 3.135V
3.V
IH
(max) is acceptable 5.6V AC pulse width with
≤
3ns of duration
4.V
IL
(min) is acceptable -2.0V AC pulse width with
≤
3ns of duration
AC OPERATING CONDITION
(TA=0 to 70
°
C
, V
DD
=3.3
±
0.3V
Note2
, V
SS
=0V)
Note :
1. Output load to measure access time is equivalent to two TTL gates and one capacitor (50pF)
For details, refer to AC/DC output circuit
2.VDD(min) of HY57V641620HG(L)T-5/55/6 is 3.135V
Parameter
Symbol
Rating
Unit
Ambient Temperature
T
A
0 ~ 70
°
C
Storage Temperature
T
STG
-55 ~ 125
°
C
Voltage on Any Pin relative to V
SS
V
IN
, V
OUT
-1.0 ~ 4.6
V
Voltage on V
DD
relative to V
SS
V
DD,
V
DDQ
-1.0 ~ 4.6
V
Short Circuit Output Current
I
OS
50
mA
Power Dissipation
P
D
1
W
Soldering Temperature
⋅
Time
T
SOLDER
260
⋅
10
°
C
⋅
Sec
Parameter
Symbol
Min
Typ.
Max
Unit
Note
Power Supply Voltage
V
DD
, V
DDQ
3.0
3.3
3.6
V
1,2
Input High Voltage
V
IH
2.0
3.0
V
DDQ
+ 2.0
V
1,3
Input Low Voltage
V
IL
V
SSQ
- 2.0
0
0.8
V
1,4
Parameter
Symbol
Value
Unit
Note
AC Input High / Low Level Voltage
V
IH
/ V
IL
2.4/0.4
V
Input Timing Measurement Reference Level Voltage
Vtrip
1.4
V
Input Rise / Fall Time
tR / tF
1
ns
Output Timing Measurement Reference Level
Voutref
1.4
V
Output Load Capacitance for Access Time Measurement
CL
50
pF
1
- 2 0 -