23
In order to maintain generator’s performance:
• Always connect the generator to the ground terminal to prevent
electrical shock.
• Add the watt ratings of all the loads that the generator set will be
powering at the same time. Make sure that total wattage will not exceed
the generator rating.
EXAMPLE:
A generator set rated 5000W can power two 1500W heaters, a 900W circular saw,
a 500W drill and a 100W light at the same time (4500W combined). However, to
operate a second 900W saw, it will be necessary to disconnect one of the 1500 W
heaters.
During operation, ensure that the generator is running properly. Check for
excessive vibration and sudden drops in the running volume.
Check the color of the exhaust - if it is noticeably black or white, this is an
indication of an improper fuel-to-air mixture or a system overload.
USING DC OUTPUT TERMINALS
You can use 12V 8.3A DC output to charge automotive batteries. Be sure to
monitor the battery charge time.
Over-charge may cause explosion and injury
1. Connect the positive (red) terminal of the battery to the red (positive)
terminal the 12V 8.3A dC Output Terminal on the front panel
2. Connect negative(black) terminal of the battery to the black (negative)
terminal of the 12V 8.3A dC Output terminal on the front panel (dO NOT
REVERSE POLARITY OF CONNECTIONS)
3. Start the generator according to section 4.3
Summary of Contents for HCP6500D
Page 1: ...1 Diesel Powered Generator User Manual ...
Page 3: ...3 ...
Page 4: ...4 ...
Page 11: ...11 COMPONENTS 2 1 Identification of Components ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 33: ...33 8 0 WIRING DIAGRAMS ...
Page 38: ...38 ...
Page 39: ...39 ...