ISSUE
CAUSE
ACTION
Engine cranks
slowly
Engine oil is too heavy
Replace with recommended oil
Load is connected
disconnect load while starting
Engine is not
starting
Insufficient fuel
Refill fuel tank
Air in fuel line
Purge air from fuel circuit
No spray from injector (or in small
amounts)
Repair and adjust fuel injector - contact
customer service
Low oil level
Add more oil
dirty nozzle
Clean nozzle
No charge in battery
Charge or replace battery
Black exhaust
Choke stuck in closed position
Open choke
dirty air filter
Clean air filter
Rich fuel mixture
Contact customer service
Engine stops
No fuel
Refill fuel tank
Not enough oil
Add more oil
Engine has
difficulty idling
Generator set not level
Move generator to a level surface
dirty fuel filter
Replace the filter
No AC Output
Tripped AC circuit breaker
Remove all loads, reset breaker and check
loads for defects. do not exceed genera-
tor rating.
No dC Output
Tripped dC circuit breaker
disconnect battery, reset breaker and test
battery for short circuit
No charge in
Electric Start
Battery
Corroded battery posts
Clean battery posts
Battery cable is damaged
Replace cable
Battery is defective
Check for damage, replace if required
No output display
or no LEd lights
Electric start battery is not connected
Connect battery
Summary of Contents for HCP6500D
Page 1: ...1 Diesel Powered Generator User Manual ...
Page 3: ...3 ...
Page 4: ...4 ...
Page 11: ...11 COMPONENTS 2 1 Identification of Components ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 ...
Page 33: ...33 8 0 WIRING DIAGRAMS ...
Page 38: ...38 ...
Page 39: ...39 ...