Protection of the environment

You must periodically check the silencer (Before doing this, switch off the generator and let it
cool completely). A damaged silencer increases noise.

Do not throw motor oil into the drains but deposit it at a collection point set up for that purpose.

The fuel for this machine is combustible and explosive. After stopping the machine, you must
handle the remaining fuel correctly and meet local environmental requirements.

To dispose of residual fluids, proceed as follows:

Close the fuel tap

Drain fuel from the fuel tank

Empty carburetor fuel

Symbol explanation

Attention!

Please read the manual carefully before using the unit!

Conforms to relevant safety standards

Do not dispose of old appliances with domestic rubbish.

Add engine oil.

Guaranteed sound power level

No naked flames

Ground connection

Electrical hazard

Carbon monoxide (CO)danger

Fire hazard

Risk of being burnt

Summary of Contents for HG4000-A

Page 1: ...1 EN LOW POWER GENERATING SET HG4000 A WARNING Read thoroughly the instruction manual before use...

Page 2: ...AC Operation 5 DC Operation If available 6 High Altitude Operation 6 PRE OPERATION CHECK 1 Engine Oil 2 Fuel Recommendation 7 STARTING STOPPING THE ENGINE 8 MAINTENANCE 1 Maintenance Schedule 2 Tool K...

Page 3: ...se do not use this device when people especially children or pets are nearby Direct them away from the working area The operator or the user are responsible for possible accidents or damage to other p...

Page 4: ...generator with the cord watch out for sudden changes in the rotation of the motor Risk of wounding Never cover the generator when it is running The cut out mounted on the generator has the aime of re...

Page 5: ...mely start up is not possible The adjustment of this machine must not be modified or altered by the operator In case of adjustment it shall be provided by a qualified professional Security measures wh...

Page 6: ...thick to transport the current and that they are used correctly The connection of a generator used for auxiliary power to the electrical installation of a building must be performed by a qualified el...

Page 7: ...he machine you must handle the remaining fuel correctly and meet local environmental requirements To dispose of residual fluids proceed as follows Close the fuel tap Drain fuel from the fuel tank Empt...

Page 8: ...8 Warnings on product Read them carefully before use the tool...

Page 9: ...2 COMPONENT IDENTIFICATION NOTE Diagrams may vary according to the types Set nameplate MOTOR SWITCH CIRCUIT BREAKER LEVIER THE STARTER FUEL VALVE AIR FILTER STARTER REEL HANDLE OIL FILTER CAP AC OUTLE...

Page 10: ...lace 2 Foot pad Keep the tool upside down In the food pad 2 pieces put a washer and a screw on each foot pad Localise the two holes on the bar Screw each foot bar in each hole 3 Handles Put the tool i...

Page 11: ...t a time If the engine fails to start release the switch and wait 10 seconds before operating the starter again 2 Recoil Starter To start the engine pull the starter grip lightly until resistance is f...

Page 12: ...6 Ground Terminal The generator ground terminal is connected to the panel of the generator the metal non current carrying parts of the generator and the ground terminals of each receptacle Before usin...

Page 13: ...uld be grounded Connect a length of heavy wire between the ground terminal and the ground source The generators have a system ground that connects generator frame components to the ground terminals in...

Page 14: ...r to switch OFF reduce the electrical load on the circuit wait a few minutes and then reset the circuit breaker 5 High Altitude Operation At high altitude the standard carburetor air fuel mixture will...

Page 15: ...temperature use Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range 1 Remove the oil filler cap and wipe the dipstick clean 2 Chec...

Page 16: ...ting under heavy loads This is no cause for concern If spark knock or pinging occurs at a steady engine speed under normal load change brands of gasoline If spark knock or pinging persists see an auth...

Page 17: ...d plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under warranty 6 STARTING STOPPING THE ENGINE Starting the engine 1 Make sure that the A...

Page 18: ...lso help reduce air pollution WARNING Exhaust gas contains poisonous carbon modoxide Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilat...

Page 19: ...ditions If you operate your generator under severe conditions such as sustained high load or high temperature operation or use it in unusually wet or dusty conditions consult your servicing dealer for...

Page 20: ...o the carburetor To prevent carburetor malfunction service the air cleaner regularly Service more frequently when operating the generator in extremely dusty areas WARNING Using gasoline or flammable s...

Page 21: ...om around the spark plug base 3 Use the wrench supplied in the tool kit to remove the spark plug 4 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clean the spark plu...

Page 22: ...oring the generator Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator Before storing the unit for an extended period Be sure the storage area...

Page 23: ...poon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil then reinstall the spark plug 4 Slowly pull the starter grip until resistance is felt At this poin...

Page 24: ...gnite To check 1 Remove the spark plug cap and clean any dirt from around the spark plug 2 Remove the spark plug and install the spark plug in the plug cap 3 Set the plug side electrode on the cylinde...

Page 25: ...circuit breaker ON Check the electrical appliance or equipment for any defects YES NO Take the generator to an authorized generator dealer NO DEFECTS Replace the electrical appliance or equipment Tak...

Page 26: ...26 11 CIRCUIT DIAGRAM...

Page 27: ...g kW h 349 g kW h Lube Oil capacity L 1 1 L Sound pressure level LpA 74 6 dB A K 1 95 dB A Measured sound power level LwA 94 6 dB A K 1 95 dB A Guaranteed sound power level 97 dB A Generator SET Gene...

Page 28: ...2014 30 EU Rohs Directive EU 2015 863 amending 2011 65 EU Emission directive EU 2016 1628 2018 989 EU Noise directive 2000 14 CE Annex VI 2005 88 CE Also complies with European standards with national...

Page 29: ...user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the information co...

Page 30: ...fore dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is comp...

Page 31: ...ssary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair sta...

Page 32: ...29...

Reviews: