28.
EN
6. TROUBLESHOOTING
The following table is a troubleshooting guide for diagnosing the
generator set. If these recommendations cannot solve the problem,
please contact our service center.
Many troubleshooting procedures present hazards which
can result in severe personal injury or death. Only trained
and experienced service personnel with knowledge of
fuels, electricity, and machinery hazards should perform
service procedures. Review Safety Precautions.
A hot generator can cause severe burns. Always allow
the generator set to cool before performing any
maintenance service.
WARNING
Engine Troubleshooting:
If engine won’t start, low engine output and engine run erratically
For insufficient compression:
Probable Cause
Corrective Action
Loose spark plug
Tighten plug properly
Loose cylinder head bolt
Tighten bolt properly
Damaged gasket
Replace gasket
If the compression is sufficient:
Probable Cause
Corrective Action
No fuel supplied to combustion
chamber, insufficient pulling speed
for starting rope
Pull rope sharply
No fuel supplied to combustion
chamber, foreign matter in fuel tank
clean tank