3-71
Fault code
(Hex)
Meaning of the fault code
possible reason for fault detection
Reaction of the TCU
Possible steps to repair
BB
Slippage at converter lockup clutch
TCU calculates a differential speed at
closed converter lockup clutch. If this
calculated value is out of range, TCU
interprets this as slipping clutch
·
Low pressure at converter lockup clutch
·
Low main pressure
·
Wrong signal at engine speed sensor
·
Wrong signal at turbine speed sensor
·
Wrong size of the sensor gap
·
Clutch is defective
No reaction
OP mode : Normal
·
·
·
·
·
·
·
Check pressure at converter lockup
clutch
Check main pressure in the system
Check sensor gap at engine speed
sensor
Check sensor gap at turbine speed
sensor
Check signal at engine speed
sensor
Check signal at turbine speed
sensor
Replace clutch
C0
Engine torque or engine power overload
TCU calculates an engine torque or
e n g i n e p o w e r a b o ve t h e d e f i n e d
thresholds
OP mode : Normal
C1
Transmission output torque overload
TCU calculates an transmission output
torque above the defined threshold
OP mode : Normal
C2
Transmission input torque overload
TCU calculates an transmission input
torque above the defined threshold
programmable :
No reaction or shift to
neutral
OP mode : Normal
C3
Overtemp converter output
TCU measured a oil temperature at the
conver ter output that is the allowed
threshold
No reaction
OP mode : Normal
·
·
·
Cool down machine
Check oil level
Check temperature sensor
C4
S. C. t o g r o u n d a t j oy s t i ck s t a t u s
indicator
TCU detected a wrong voltage at the
output pin, that looks like a S.C. to vehicle
ground
·
Cable is defective and is contacted to
vehicle ground
·
Joystick status indicator has an internal
defect
·
Connector pin is contacted to vehicle
ground
No reaction
OP mode : Normal
·
·
·
Check the cable from TCU to
joystick status indicator
Check the connectors from joystick
status indicator to TCU
Check the resistance* of joystick
status indicator
* See page 3-74
C5
S.C. to battery voltage at joystick status
indicator
TCU detected a wrong voltage at the
output pin, that looks like a S.C. to battery
voltage
·
Cable is defective and is contacted to
battery voltage
·
Joystick status indicator
has an internal
defect
·
Connector pin is contacted to battery
voltage
No reaction
OP mode : Normal
·
·
·
Check the cable from TCU to
joystick status indicator
Check the connectors from joystick
status indicator to TCU
Check the resistance* of joystick
status indicator
* See page 3-74
※
Some fault codes are not applied to this machine.