3-198
Mount stud bolts (1).
Wet screw-in thread with loctite (type No.
243).
·
Tightening torque (M8/10.9
×
25) :
1.53 kgf
·
m (11.1 lbf
·
ft)
Place seal (2) and duct plate (3) at the
housing rear par t until contact is
obtained.
Use assembly grease.
Fix duct plate (1) by means of Torx
screws (2) and hexagon nuts (3).
·
Tightening torque (M8/10.9
×
30) :
2.35 kgf
·
m (17.0 lbf
·
ft)
·
Tightening torque (M8) :
2.35 kgf
·
m (17.0 lbf
·
ft)
Mount screw plug (4) with new O-ring 13
×
2.
·
Tightening torque (M16
×
1.5) :
3.06 kgf
·
m (22.1 lbf
·
ft)
Socket wrench TX-40
5873 042 004
7609ATM391
7609ATM392
Fit two adjusting screws.
Adjusting screws
5870 204 063
Mount sealing plate (1) and electro-
hydraulic control unit (2).
It is not permitted to reassemble the seal
plate after opening the threaded joint
shift unit/gearbox housing.
In case of repair it is always necessary to
mount a new seal plate.
7609ATM394
Mount compression spring (4), piston (3)
and switch (2) with new O-ring 13
×
2.
1 Filter differential pressure valve
2 Switch with O-ring
3 Piston
4 Compression spring
·
Tightening torque :
3.06 kgf
·
m (22.1 lbf
·
ft)
7609ATM393
※
※
21
※
22
23
24
2
1
3
2
1
1
3
4
1
2
3
4
2
S
Summary of Contents for HL955
Page 557: ...7 6 MEMORANDUM MEMORANDUM ...